Getting started
Bracket Setup for Installation
AC 24V Output (for Heater connection)
12
SPEED DOME CAMERA
Video Out
Alarm In 1
Alarm In 2
Alarm In 3
Alarm In 4
Alarm Out 1
Alarm Out 2
Mainframe 18PIN Connector
Initial Setting
● Communication Protocol Setting (Installation Bracket)
Select and set SW1 on the installation bracket for setting the communication protocol.
SW1
0
1
2
3
4
5~F
Note) Factory Default : 0 (Samsung, 9600)
● Baud Rate Setting by DVR Model
For control of the speed dome camera using DVR without a dedicated controller, set the baud rate by DVR
model as described below.
Protocol
DVR Model
SVR-430
SVR-900/1620
SVR-1630
Note) A faster rate may degrade stability.
The control function may not be available depending on the DVR Firmware version.
Be sure to install the latest DVR Firmware version.
● Camera ID Setting (Mainframe front panel)
·
Set the Camera ID using the two rotary switches. SW1 and SW2
refer to the lower and upper positions, respectively.
·
EX) If the camera ID is number 1, set as described below.
Protocol
Baud Rate (BPS)
Samsung
9,600
Samsung
19,200
Pelco-D
2,400
Pelco-D
4,800
Pelco-D
9,600
Reserve
Samsung
Pelco
9600,19200
9,600
9600,19200
4800, 9600
9600,19200
2400,4800,9600
SW2
SW1
0
1
SW2
SW1
SPEED DOME CAMERA