• Adjustment Method of REG3_LOW1
(item number: 747)
Set LCD display
REG3L1 **
** : Adjusted value
1. Connect a digital voltmeter to the TP1907 (REGO3) on the
[SPEED CONTROL +]
MAIN board, and adjust
[SPEED CONTROL --]
up) or
voltage becomes 1.25 ± 0.01V.
MAIN board
TP1907 (REGO3)
TP1616 (GND)
2. Press the
key on the set or the
X
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
• Adjustment Method of REG3_LOW2
(item number: 748)
Set LCD display
REG3L2 **
** : Adjusted value
1. Connect a digital voltmeter to the TP1907 (REGO3) on the
[SPEED CONTROL +]
MAIN board, and adjust
[SPEED CONTROL --]
up) or
voltage becomes 1.25 ± 0.01V.
MAIN board
TP1907 (REGO3)
TP1616 (GND)
2. Press the
key on the set or the
X
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
747
key (voltage
key (voltage down) so that the
digital
voltmeter
key on the remote
(see page 25)
748
key (voltage
key (voltage down) so that the
digital
voltmeter
key on the remote
(see page 25)
• Adjustment Method of REG3_HIGH
(item number: 749)
Set LCD display
REG3 H **
** : Adjusted value
1. Connect a digital voltmeter to the TP1907 (REGO3) on the
[SPEED CONTROL +]
MAIN board, and adjust
[SPEED CONTROL --]
up) or
voltage becomes 1.25 ± 0.01V.
MAIN board
TP1907 (REGO3)
TP1616 (GND)
2. Press the
key on the set or the
X
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
• Adjustment Method of VREC_LOW (X2 speed)
(item number: 751)
Set LCD display
VREC L **
** : Adjusted value
1. Connect a digital voltmeter to the TP1620 (VREC) on the
[SPEED CONTROL +]
MAIN board, and adjust
[SPEED CONTROL --]
up) or
voltage becomes 1.10 ± 0.01V.
MAIN board
TP1620 (VREC)
TP1616 (GND)
2. Press the
key on the set or the
X
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
MZ-B10
749
key (voltage
key (voltage down) so that the
digital
voltmeter
key on the remote
(see page 25)
751
key (voltage
key (voltage down) so that the
digital
voltmeter
key on the remote
(see page 25)