Sony MZ-S1 Service Manual page 22

Hide thumbs Also See for MZ-S1:
Table of Contents

Advertisement

MZ-S1
[VOL +]
23) Adjust with the
key (adjusted value down) so that the adjusted value becomes
5B.
24) Press the
key to write the adjusted value.
X
25) Select manual mode of the test mode, and set item number
777 (see page 16).
Set LCD display
777
** : Adjusted value
[VOL +]
26) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7B.
27) Press the
X
key to write the adjusted value.
28) Select manual mode of the test mode, and set item number
778 (see page 16).
Set LCD display
778
** : Adjusted value
[VOL +]
29) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7D.
30) Press the
key to write the adjusted value.
X
31) Select manual mode of the test mode, and set item number
779 (see page 16).
Set LCD display
779
** : Adjusted value
[VOL +]
32) Adjust with the
key (adjusted value down) so that the adjusted value becomes
7F.
33) Press the
key to write the adjusted value.
X
34) Select manual mode of the test mode, and set item number
781 (see page 16).
Set LCD display
781
** : Adjusted value
[VOL +]
35) Adjust with the
key (adjusted value down) so that the adjusted value becomes
81.
36) Press the
X
key to write the adjusted value.
22
[VOL --]
key (adjusted value up) or
AD **
[VOL --]
key (adjusted value up) or
AD **
[VOL --]
key (adjusted value up) or
AD **
[VOL --]
key (adjusted value up) or
AD **
[VOL --]
key (adjusted value up) or
37) Select manual mode of the test mode, and set item number
865 (see page 16).
Set LCD display
865
###S**
### : Address
** : Adjusted value
[VOL +]
38) Adjust with the
key (adjusted value down) so that the adjusted value becomes
2C.
39) Press the
X
key to write the adjusted value.
40) Select manual mode of the test mode, and set item number
866 (see page 16).
Set LCD display
866
###S**
### : Address
** : Adjusted value
[VOL +]
41) Adjust with the
key (adjusted value down) so that the adjusted value becomes
B9.
42) Press the
key to write the adjusted value.
X
43) Select manual mode of the test mode, and set item number
867 (see page 16).
Set LCD display
867
###S**
### : Address
** : Adjusted value
[VOL +]
44) Adjust with the
key (adjusted value down) so that the adjusted value becomes
C9.
45) Press the
key to write the adjusted value.
X
46) Select manual mode of the test mode, and set item number
868 (see page 16).
Set LCD display
868
###S**
### : Address
** : Adjusted value
[VOL +]
47) Adjust with the
key (adjusted value down) so that the adjusted value becomes
80.
48) Press the
X
key to write the adjusted value.
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or
[VOL --]
key (adjusted value up) or

Advertisement

Table of Contents
loading

Table of Contents