Electrical Adjustments - Sony MZ-S1 Service Manual

Hide thumbs Also See for MZ-S1:
Table of Contents

Advertisement

MZ-S1
OUTLINE
• In this set, automatic adjustment of CD and MO can be per-
formed by entering the test mode.
However, before starting automatic adjustment, the memory
clear, power supply adjustment, and laser power check must be
performed in the manual mode.
• A key having no particular description in the text, indicates a
set key.
PRECAUTIONS FOR ADJUSTMENT
1. Adjustment must be done in the test mode only.
After adjusting, release the test mode.
2. Use the following tools and measuring instruments.
• Test CD disc
TDYS-1
• SONY MO disc available on the market
• Digital voltmeter
• Laser power meter
LPM-8001
• Thermometer (using the Temperature Correction)
3. Unless specified otherwise, supply DC 3V from the DC IN
3V jack (J601).
4. Switch position
HOLD switch ............................................... ON
ADJUSTMENT SEQUENCE
1. NV Reset (EEPROM clear)
r
2. Power Supply Manual Adjustment
r
3. Temperature Correction (item number: 015)
r
4. Laser Power Check
r
5. Electrical Offset Adjustment
Caution: This adjustment must be made with
no disc loaded.
r
6. CD Overall Adjustment
r
7. MO Overall Adjustment
r
8. RESUME Clear
Note: If the version of the microcomputer is 1.000 or later, "3. Tempera-
ture Correction" and "2. Power Supply Manual Adjustment" can
be performed continuously in reverse order with pressing the
[END SEARCH]
key in the overall adjustment mode.
20
SECTION 5

ELECTRICAL ADJUSTMENTS

(Part No. : 4-963-646-01)
(Part No. : J-2501-046-A)
Manual Mode
Manual Mode
Manual Mode
Overall Mode
Manual Mode
NV RESET
Caution: The shipment data will be cleared when the NV is reset.
Therefore, change the NV adjusted values following the
Change of NV Adjusted Values immediately after the
NV was reset.
Change the NV adjustment values according to the mi-
crocomputer version.
• Setting Method of NV Reset
1. Select the manual mode of the test mode, and set item number
021 (see page 16).
Remote commander LCD display
021
###SCC
### : Address
2. Press the
X
key.
Remote commander LCD display
021
ResOK?
3. Press the
key once more.
X
Remote commander LCD display
021
Res***
NV reset (after several seconds)
Remote commander LCD display
021
Reset!
4. Press the
key to quit the manual mode, and return the test
x
mode (display check mode).