Notes On Operation; Operating Sequence & Switching Off - Stanley FUSION PELLET STOVE Operating & Installation Manual

Table of Contents

Advertisement

When refilling with pellet at this point it will take a lit-
tle while for the pellet to come through so the fire
may go to lockout again. This is normal and will light
normally once the pellet has started to feed, proba-
bly at the second attempt.

NOTES ON OPERATION

Description of front panel controls
Button 4: ON/OFF and exit programming mode
Button 3: change temperature setting
Buttons 5 and 6: UP/DOWN for thermal power set-
ting
Buttons 2 and 1: UP/DOWN for temperature set-
ting, programming functions and indicators
Upper LED display
Top left: timer program active
Bottom right: pellet auger ON
Top right: (not active)
Bottom left: (not active)
Lower LED display
Top left: heating elements ON
Top right: thermostat ON
Bottom right (flashing): temperature setting
Bottom left: lock out (ALARM)
Operation:
To start the stove, press button 4; after a few
moments, the control unit puts the stove into the
pre-ignition phase, lighting the igniter plug and
showing the message "FAN CAND" on the display;
it also switches the extractor fan on at maximum
power for about 5 seconds, then brings it down to
ignition power.
After this phase (which lasts about 90 seconds), the
message "LOAD WOOD" appears on the display
and the auger loads the pellets at the pre-set
speed.
When the smoke temperature reaches the ignition
value set by the manufacturer, the stove goes into
stabilization phase and shows the message "FIRE
ON" on the display. It then switches off the igniter
plug.
The room air ventilator (exchanger) also starts up
during the stabilisation phase.
When this phase is complete, the control unit goes
into working mode, in which the display shows the
selected thermal power value (set by buttons 5 and
6) and ambient temperature.
In this phase, buttons 5 and 6 can be used to set
the power output of the stove from 1 to 5, provided
that room temperature is below the set value, oth-
erwise power is reduced to minimum value.
If the pellets are not lit within 15 min., the stove dis-
plays the message "ALARM NO FIRE".
If there is an electrical power failure, when power is
restored, the stove expels the remaining smoke and
resumes the working program from the point at
which it stopped. It can do this only if the electrical
power was lost for a few minutes. If the stove has
cooled down during the power failure, the control
unit puts the stove back into the ignition phase, and
re-starts the program from the beginning.
To change the temperature setting at any time, sim-
ply press button 3 and use buttons 2 and 1 to adjust
the temperature shown on the lower display. During
the operating phase, the lower display indicates
ambient temperature.
When the room temperature is reached, the
stove changes from the working program into
ECO mode (pilot flame). When ambient temper-
ature falls by 2°C, the stove goes back into
working mode.
When not in setting mode, button 1 can be pressed
to show the smoke temperature on the lower dis-
play.
The stove can be switched off by pressing button 4;
in this case, the word OFF appears on the upper
display, pellet flow is stopped and extractor fan
speed increases. When cooling is complete, the
ventilator (exchanger) is switched off and, after
several minutes, the extractor fan is also switched
off.
N.B.: when the stove has cooled, the extractor is
also switched on for several minutes.
OPERATING SEQUENCE AND SWITCHING OFF
To start the stove, press button 4 on the control
panel.
The message
display for the loading time of 1.5 minutes (pre-igni-
tion phase), then the message
appears for about 4-5 minutes, during which the
burn pot is ignited and stabilised. Finally, the mes
sage
FIRE ON
appears for about 3 minutes.
7
FAN CAND
appears on the
LOAD WOOD

Advertisement

Table of Contents
loading

Table of Contents