6. Keep children away from this the stove. Do not
open the door when the stove is lit.
7. Do not switch off the electric power supply
while the stove is on. This will cause the smoke
extractor fan to stop, and the burning fuel will
cause smoke to issue into the room if there is
no natural upward draught in the chimney.
8. When the stove is lit for the first time, the var-
nish may release fumes, and these may emit
an unpleasant odour. The room must therefore
must be ventilated to evacuate these fumes.
The varnish will be fully hardened after several
heating cycles (2-3).
9. Periodically ensure that the gaskets between
stove and flue pipe are gas tight.
10. In case of fire, switch off the stove, move any
flammable materials away, and call the fire
services.

IN CASE OF CHIMNEY FIRE

Switch off appliance and close all openings into the
stove, watch for ignition of adjacent combustibles
from hot embers or sparks from chimney.

FUEL

WHAT ARE PELLETS?
PELLETS consist of sawdust or real wood scraps
ground and pressed into small cylinders about 6
mm in diameter and 20-30 mm in length.
As fuel, pellets are completely environmentally
friendly, as they are made entirely of natural wood,
without glue or other chemical compounds. Pellets
have a high calorific value (4.7 to 5.3 kW/kg), and
low moisture content.
IMPORTANT: Pellets must be stored in a dry place.
Use only good quality pellets, without sawdust.
IMPORTANT NOTICE:
sawdust normally present at the bottom of the bags
should not be emptied into the tank, but should be
held inside the bag while pouring the pellets care-
fully so that the sawdust remains inside.
If sawdust accumulates in the tank, it should be
removed periodically with a vacuum cleaner (with
the door open and disconnecting the power plug
from the electricity supply), to prevent it entering the
loading system and causing serious malfunctions.
The small quantities of
IMPORTANT: If, during a loading operation, or for
any other reason, foreign matter is allowed to enter
the tank and then the pellet loader, it may cause
damage to the internal mechanisms.
Besides causing damage, this would cause the
stove to stop. In this case, the manufacturer cannot
accept any liability.
ONLY 6mm DIAMETER PELLET MUST BE USED
DO NOT USE POOR QUALITY PELLETS OR RE-
PROCESSED PELLETS WITH HIGH SAWDUST
CONTENT. THIS TYPE OF PELLET CAN SERI-
OUSLY IMPAIR THE FUNCTIONS IN YOUR
STOVE, VOID THE WARRANTY AND THERE-
FORE RELEASE THE MANUFACTURER FROM
ALL LIABILITY.

PELLET LOADING

The pellet tank capacity is 25 Kg.
To load, lift the pellet tank lid, and pour in the pel-
lets, taking care to keep any sawdust inside the
bags.
Close the lid when loading is complete.
IMPORTANT: LOADING MUST BE CARRIED
OUT ONLY WHEN THE STOVE IS OFF AND HAS
COOLED DOWN.
Fig.10
When pellets are used up, the stove cannot work
and is therefore locked out, the display shows
"ALARM NO FIRE".