Troubleshooting installation instructions Installation/Preliminaries Inspection/Maintenance Space Required Location requirements Recommended sound attenuation for wall-mounting I nstallation of Flexit SPIRIT K2 R Installing the volume hood Connection of unit and electrical work Connection of unit Electrical work Automatic Control External components...
Page 3
important Safety instructions: It is the installer's responsibility to carry out a full safety and function assessment of the appliance To reduce the risk of fire, electric shock or injury, read all the safety instructions and warning texts before using the appliance. •...
For user Functional Description See page 15 for component description. Cold outdoor air passes through one half of the rotor (HR-R), while warm extract air passes through the other half, without the two mixing. Using this principle, a large proportion of the heat in the extract air is transferred to the supply air - the heat store principle (see system sketches).
For user 2 Cleaning/Maintenance Fans: Before opening the door of the heat recovery The fans must be cleaned once a year. Clean the fan unit or carrying out maintenance on the kitchen blades with a grease solvent on a cloth - or with brush and hood: switch off the heat, let the fans continue for three compressed air if possible.
Page 6
Do not use detergent that is harmful to aluminium or the environment. Mounting of door: Fig. 3 C ( 1 : 2 ) C ( 1 : 2 ) 1. Lower the front edge of the door into the leading edge of C ( 1 : 2 ) the unit.
Page 7
For user Kitchen hood: To change the fluorescent tube, remove the lamp glass Wipe the volume hood with a damp cloth and detergent. by pressing the snap locks in the direction of the arrow, The filter must be cleaned roughly twice a month with normal Fig.
For user Maintenance table Component interval Filters Filters should be changed at least once a year. You are advised to change them twice a year. 6-12 months Before and after the pollen season. Check that the filter seal is completely tight. Fans Fans should be cleaned at least once a year to maintain fan efficiency.
For user 4 troubleshooting In the case of a power cut, the unit will automat- ically return to normal operation (user's settings) when starting up again. The unit has a safety switch which cuts off power when the door is removed. type of fault: Remedial action: Cold draughts...
For fitter iNStAllAtiON iNStRUCtiONS 5 installation/Preliminaries 5.3 location requirements The unit has been designed for location in the kitchen over See separate documentation for installation of ducts, valves, the cooker as it contains an integrated kitchen hood. The etc. unit is available in left or right versions (exhaust air nipple to the left or right), depending on what is The unit is designed for indoor installation.
For fitter 5.4 Recommended sound attenuation for wall-mounting For wall mounting, the (included) wall bracket fixed to the unit is used. The unit must not be placed on a wall with rooms on the other side which are sensitive to noise. The wall must be sound-insulated.
Fig. 10 B=2mm B=2mm 596 mm Flexit SPIRIT K2 R is designed for installation in the kitchen above the cooker, see Fig. 11. The unit is supplied in left and right-hand versions depending on what suits duct locations best (Chap. 5.1).
For fitter Connection of unit and electrical 7.3 Automatic Control work The control pack is included in the unit package. The low-voltage cable must be laid between the unit and the switch unit. See separate manual for automatic control 7.1 Connection of unit included in pack.
For fitter 9 General Drawings and System Drawings (Shown as left-hand model. The right-hand version is a mirror image.) Outdoor Supply Extract Exhaust air air air General Diagram (Rotary Wheel-type Heat Exchanger) 1 (FI2) Extract filter F 7 2 (FI1) Supply air filter F 7 3 (EB1) Heating element...
For fitter 10.2 Capacity diagram, sound data, specifications - K2 R eC Supply air side (with F7 filter) 100% 100% Yellow field: SFP < 1.0 per fan 70dB(A) 65dB(A) 60dB(A) 55dB(A) Air flow rate, m /h - Pressure correction factor Extract air side (with F7 filter) 100% 100%...
For fitter 11 technical data 11.1 technical data Flexit SPiRit K2 R Rated voltage 230 V/50 Hz 230 V/50 Hz Fuse size 10 A 10 A Rated current, total 3.85 A 4.0 A Rated power, total 900 W 930 W...
For fitter B ( 1 : 1 ) 12 Adjusting the Kitchen Hood If basic ventilation is desired via the kitchen hood, the damper from the factory must be replaced. Replace it with a damper with adjustment options. This is not supplied with the unit.
For fitter 13 Adjustment Curves 13.1 Forced ventilation Flexit SPiRit K2 R Max. air volume through kitchen hood in case of forced air volume Measurements have been taken at 2/3 pressure in the extract air duct and 1/3 pressure in the exhaust air duct...
• The unit has filters for both outdoor air and extract air. • Tumble dryers must not be connected to the unit. The installer may be held liable for any incorrect or defective installation. Flexit SPIRIT K2 R, Left-hand model Flexit SPIRIT K2 R, Right-hand model...
Council Directives and standards: 89/336/eeC electromagnetic Compatibility (eMC) 73/23/eeC low-voltage Directive (lVD) 98/37/eeC Machine Directive (Safety) Manufacturer: FLEXIT AS, Televeien 15, 1870 Ørje, Norway type: K2 R Ventilation unit Conforms to following standards: Safety standard EN 60335-1:2002...
Need help?
Do you have a question about the Spirit K2R and is the answer not in the manual?
Questions and answers