7-1-7. Louver Control

When the air-conditioner is turned on, the motor of upper and lower swing will enable the louver to be open
and then close completely (the air outlet is closed).
In heating mode, if the swing function is not set, the upper and lower louver will rotate to maximum in clockwise
direction. Then, it will rotate to place "D".
Under other state, the upper and lower louver will rotate to place "L".
If the swing function is set when starting the air-conditioner the louver will swing between place "L" and "D".
There are 7 states for the louver: in place "L", "A", "B", "C", "D", and swing between "L" and "D", stop in any
place between "L" and "D".
When the air-conditioner is turned off, the louver will stay in place "O".
The swing is available only when the swing function is set and the indoor fan is running.
When place "L" to "B", place "A" to "C", and place "B" and "D" is set, the louver will swing between
NOTE
place "L" to "D".