7-1-9. Timer Function

The main board has general timer function and clock function.
The timer function can be selected by remote controller with different function.
A. General Timer
Start and stop time can be set. The accuracy is minute.
e.g. Timer on for 1 hour; timer off for 1.5 hours
Timer ON
: After setting timer on, the air-conditioner will run at setting time according to the original
setting mode. The timing interval is 0.5 hour, and the setting range is 0.5 to 24 hours.
Timer OFF : The timer off function can be set when the air-conditioner is on.
When the setting for timer off is reached, the air-conditioner will stop.
the timing interval is 0.5 hour, and the setting range is 0.5 to 24 hours.
B. Clock Timer
Start and stop time can be set. The accuracy is minute.
e.g. Timer on at 8:00 a.m.; timer off at 17:30 p.m.
Timer ON
: If the timer on function is set when the air-conditioner is on, the air-conditioner will go running.
If the timer on function is set when the air-conditioner is off, the air-conditioner will start
running in the previously set mode when the setting time is reached.
Timer OFF : The timer off function is set when the air-conditioner is off, the air-conditioner will keep off
even though the setting time is reached.
If the timer off function is set when the air-conditioner is on, the air-conditioner will stop
running when the setting time is reached.
1. Setting time change
NOTE
When the air-conditioner is under timer state, start or stop of the air-conditioner can be set by
remote controller ON/OFF button and timer can be reset.
The air-conditioner runs according to the latest setting state.
2. When both the timer on and off are set, the air-conditioner runs according to the current setting
state. When the setting time is reached, the air-conditioner will start and stop running. In that
case, the air-conditioner will run according to the previously setting mode when the setting time
for timer on is reached .
The air-conditioner will stop running while the setting time for timer off is reached.
If the setting time for timer on and off is the same, the air-conditioner will stop running no matter
what the current state is.