Installation Details - Vent-a-Hood M600 Installation Instructions Manual

M600 or m1200 blower

Advertisement

1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard liners only.
Custom liners may require additional specification consideration.
2) When installing a MSLD wall mount liner (19 1/4" deep), it is recommended that the bottom edge of the liner be located
no more than 24" - 27" from the cooking surface. For MPSLD wall mount liners (22 1/2" deep), it is recommended that
the bottom edge of the liner be located no more than 27" - 30" from the cooking surface. Exceeding recommended
mounting height may compromise performance.
MSLD Liner
3) Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the liner allowing
room for the transition (if applicable). If a transition is used, install duct down to the location of the transition outlet
plus 1". This will allow the transition to engage 1" inside of duct. Consult the connection diagrams (below) for further
details on exhaust outlet placement.
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is included on the back
page of this instruction sheet.
Transition heights are as follows:
Single Blower (M600):
Dual Blower (M1200):
M600 Connection Diagram

6" Round
Centerline
of Hood
Single Blower
(Top View)
L154 0311A

Installation Details

6" round duct will connect directly to the top of the liner.
Included 10" round transition (VP566) is 9" tall.

Electrical
M1200 Connection Diagram


10" Round
Centerline
of Hood
Page 3
MPSLD Liner

Electrical
Dual Blower
(Top View)