WAECO. Bestellen Sie einfach unsere Kataloge kostenlos und unverbindlich unter der Internetadresse: www.dometic-waeco.de We will be happy to provide you with further information about WAECO products. Please order our free catalogue with no obligation to buy on our homepage: www.dometic-waeco.com Demandez d’autres informations relatives à...
Notes on using the operating manual COOLMATIC MDC Series Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is resold, this operating manual must be handed over to the purchaser along with it. Contents Notes on using the operating manual .
1 in figure 2 on page 3. Please observe the following safety instructions. Safety instructions Caution! WAECO International will not be held liable for claims for damage resulting from the following: Damage to the device resulting from mechanical influences and overvoltage...
Intended use COOLMATIC MDC Series Before starting up the device for the first time, check whether the operating voltage and the battery voltage correspond (see type plate). Danger of fatal injuries! When using the device on boats: if the device is powered by the mains, ensure that the power supply has a ground fault interrupter circuit.
COOLMATIC MDC Series Scope of delivery Scope of delivery Quantity Description Refrigerator Assembly kit for changing the door hinge Operating manual Accessory If you wish to operate the cooling device with a 230 V AC mains supply, please use one of the following rectifiers: Description Item number MOBITRONIC rectifier...
On the MDC-90 and MDC-110 models the temperature control and the error code LED are on the device operating panel. On the MDC-50 and MDC-65 models, the temperature control and the LED are integrated in the device. Setting up and connecting the cooling...
Page 11
COOLMATIC MDC Series Setting up and connecting the cooling device Sealing system The cooling device has a locking mechanism to protect it during transport. The following settings are possible: – Position 1 (transport lock): (fig. 3 1, page 4) The door is locked and secured.
Page 12
Setting up and connecting the cooling device COOLMATIC MDC Series Changing the decorative plate You can change the decorative plate on your cooling device to improve the appearance. This is how to change the decorative plate: ➤ Remove the screws 1 and 3 (fig. 5 1 and 3, page 5). ➤...
Page 13
COOLMATIC MDC Series Setting up and connecting the cooling device Connecting to a battery The cooling device can be operated with a 12 V or 24 V DC voltage supply. To avoid voltage loss and therefore a drop in performance, the cable should be kept as short as possible and should not be interrupted if this is possible.
Operation COOLMATIC MDC Series Connecting to 230 V mains supply Danger of fatal injuries! Never handle plugs and switches with wet hands or if you are standing in a puddle. If you are operating your cooling device on board a boat with a mains connection of 230 V from the land, you must install a ground protection circuit breaker between the 230 V mains supply and the cooling device.
Page 15
COOLMATIC MDC Series Operation ➤ Switch the cooling device on by turning the knob (fig. 1 A, page 3) to the right. After switching on, the cooling device requires approx. 60 s until the compressor starts up. Caution! Ensure that the objects placed in the cooling device are suitable for cooling to the selected temperature.
Page 16
Operation COOLMATIC MDC Series Wrap food in aluminium foil or cling film and shut it in a suitable box with a lid. This ensures that aromas, the shape and the freshness are better conserved. Securing the refrigerator door You can prevent the refrigerator door from being opened inadvertently. ➤...
COOLMATIC MDC Series Cleaning and maintenance Cleaning and maintenance Caution! Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the cooling device. Caution! Never use brushes, scouring pads or hard or pointed tools to remove ice or to loosen objects which have frozen in place.
Troubleshooting COOLMATIC MDC Series Troubleshooting Error code LED The error code LED indicates various faults with a different number of flashes. One flash lasts a 1/4 of a second. The error codes are repeated every 4 seconds. Number of Error type Possible cause flashes Battery protection shut...
Page 19
COOLMATIC MDC Series Troubleshooting Switch-off voltage of the electronics Interior temperature too low in control setting 1 Fault Possible cause Remedy Compressor runs Thermostat sensor has no contact to Secure the sensor constantly the vaporiser Thermostat defective Change the thermostat Short circuit in the thermostat line Compressor runs for a A large quantity has been frozen in the...
– Cooling device compartment temperature: +10 °C to +2 °C – Freezer compartment temperature: 0 °C to –18 °C – Relative humidity: maximum 90 % – Constant inclination: maximum 30° – Test/certificates: complies with ErP/EuP directive MDC-50 MDC-65 Overall capacity: 43 l 64 l Freezer compartment:...