Installation - LG L2-C362LL0 Service Manual

Multi type air conditioner
Table of Contents

Advertisement

Installation

Installation
(1) Installation of Indoor, Outdoor unit
1) Selection of the best location
1. Indoor unit
There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent
the air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful that
heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by hot air discharged.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation
Pipe Size
Capacity
(Btu/h)
GAS
10, 12K
1/2"(3/8")
18K
5/8:
24K
5/8"
46 Multi Air Conditioner
Max.
Max. piping
Elevation
length
LIQUID
B (m)
A (m)
1/4"
15
1/4"
20
3/8"
30
Right
More than
5 cm
More than eye-level
More than 20 cm
More than
70 cm
Indoor unit
7
10
15
Front
Down right
Rear right
More than 5 cm
More than 20 cm
A
B
Outdoor unit
Left
Rear left
More than
5 cm