Installing Grass Screen; Install Oil Sentry Or Pipe Plug; Installing Pipe Plug Or Adapter; Install Air Cleaner Element, Precleaner, And Air Cleaner Cover - Kohler Courage SV470-600 Service Manual

Vertical crankshaft courage series
Table of Contents

Advertisement

Section 10
Reassembly
Figure 10-72. Installing Grass Screen.
Install Oil Sentry™ or Pipe Plug
1. Apply pipe sealant with Teflon
59241 or equivalent), to the threads of the 1/8"
pipe plug or adapter. Install and tighten into the
port on the closure plate. See Figure 10-73.
Torque pipe plug to 4.5-5.0 N·m (40-45 in. lb.). If
a switch was installed, apply sealant to the
threads of the Oil Sentry™ switch and install into
the adapter or center passage. Torque the switch
to 4.5-5.0 N·m (40-45 in. lb.). Connect the green
wiring harness lead to the terminal on the switch.
See Figure 10-74.
Figure 10-73. Installing Pipe Plug or Adapter.
10.20
www.SmallEngineDiscount.com
Figure 10-74. Installed Oil Sentry™ Switch.
Install Air Cleaner Element, Precleaner,
®
(Loctite
®
No.
and Air Cleaner Cover
1. Install the air cleaner element with the pleated
Center Passage
Figure 10-75. Installing Air Cleaner Element.
2. Install the precleaner (if so equipped), into the
Not For Resale
side "out." Seat the rubber seal onto all the edges
of the air cleaner base. See Figure 10-75.
upper section of the air cleaner cover. See Figure
10-76.
Oil Sentry™
Switch

Hide quick links: