4. Voltage
S Connect the pocket tester (DC 20 V) to the
flasher relay coupler.
Tester (+) lead ! Brown terminal
Tester (–) lead ! Frame ground
S Turn the main switch to "ON".
S Check the voltage (12 V) of the "Brown"
lead at the flasher relay terminal.
5. Voltage
S Connect the pocket tester (DC 20 V) to the
flasher relay coupler.
Tester (+) lead !
Brown/White terminal
Tester (–) lead ! Frame ground
S Turn the main switch to "ON".
S Turn the turn switch to "L"/"R" or push the
hazard switch.
S Check
the
voltage
"Brown/White"
1
lead at the flasher relay
terminal.
:
1
1
MEETS
SPECIFICATION
1
(12
V)
on
the
MEETS
SPECIFICATION
–29–
SIGNAL SYSTEM
OUT OF SPECIFICATION
The wiring circuit from the main switch to the
flasher relay connector is faulty, repair it.
OUT OF SPECIFICATION
The flasher relay is faulty, replace it.
ELEC