Kenwood NX-740H Service Manual page 9

Vhf digital transceiver
Hide thumbs Also See for NX-740H:
Table of Contents

Advertisement

2.3.8 Changing of Signal Type
2.3.8.1
Change signal input of D-SUB connector from DI to
MIC
The input (5pin) of D-SUB 15-pin connector is configured at the
DI as the default value.
Remove the R737 chip jumper and solder the chip jumper to
R735.
TX-RX unit
Component side
2.3.9 Emergency MIC
2.3.9.1
Installation Procedure
(1) Remove the two screws on both the right and left sides of
the transceiver, then remove the cabinet and top packing
from the transceiver.
(2) solder the MIC connection cable as below
a) solder the MIC +ve cable (signal line) to EMGMIC
solder pad
b) solder the -ve cable (GND) to GND solder pad
TX-RX unit
Component side
Note:
You must set up using the KPG-175D.
MIC -ve cable (GND)
MIC -ve cable (GND)
MIC -ve cable (GND)
MIC +ve cable (signal line)
MIC +ve cable (signal line)
MIC +ve cable (signal line)
(3) Dress the cable as shown in the figure. The cable needs to
pass through one of two indentations located on the rear
panel of the transceiver.
(4) Cut off the projection of the top packing using a pair of nip-
pers or similar tool.
If the cable is dressed to be routed through the indentations
on the right side in step 4, the right side of the projection
needs to be cut off.
If the cable is dressed to be routed through the indentations
on the left side, the left side of the projection needs to be
cut off.
Following is a figure presenting an example for when the
right side of the projection is cut off.
(5) Reinstall the top packing. Check the correct fitting of the
top packing, then reinstall the cabinet and two screws for
the right and left sides.
Top packing
(No.RA010<Rev.001>)1-9