Kenwood NX-740H Service Manual page 28

Vhf digital transceiver
Hide thumbs Also See for NX-740H:
Table of Contents

Advertisement

Item
Condition
5. High RSSI
[Analog Narrow]
*Note 4
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[NXDN Very Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
*Note 4:
(1) If NXDN Very Narrow RSSI tuning is selected, it will align for the NXDN Very Narrow band only.
(2) If Analog Narrow Band RSSI tuning is seleted, Analog Narrow band and NXDN Very Narrow will be align with same tuning
value.
1-28 (No.RA010<Rev.001>)
Measurement
Test-
Unit
Terminal
equipment
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
Adjustment
Unit
Parts
Method
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
Specifica-
tions
/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-740Nx-740vNx-740hv

Table of Contents