6. Removing the ballast / filter / sound-out unit assembly.
6-1. Disconnect the connector (BA) from the AC power switch.
6-2. Disconnect the ground wire from the inlet unit.
6-3. Remove the two lock screws off the ballast/filter/sound-out unit assembly. Detach the assembly.
7. Removing the power unit
7-1. Remove the three lock screws off the power PWB. Detach the power unit.
8. Removing the AC power switch and inlet unit.
8-1. Remove the two lock screws off the AC power switch, disconnect the connector (PA) from the inlet unit, and
detach the AC power switch and the inlet unit.
7-1
Power Unit
6-2
6-3
16
to Inlet Unit
Ballast/Filter/
Sound-Out Unit
Inlet Unit
8-1
(BA)
(PA)
AC Power Switch
(for Lamp replacement)
6-1