Sharp PG-C30XU Service Manual page 24

Lcd projector
Hide thumbs Also See for PG-C30XU:
Table of Contents

Advertisement

PG-C30XU
Adjusting the optical axis of the mirrors (M1, M5 and M4/M6)
The optical axis must be readjusted if an eclipse happens with the R. G or B mirrors. Generally speaking,
this adjustment is needed when any of the internal optical components has been replaced.
Adjustment procedure required when any of the panels has been replaced or the convergence has been
adjusted
(1) Disconnect the flat cables of all the LCD panels.
(2) Let the lamp light up.
(3) To adjust the G mirror, shield the R and B mirrors with shielding plates (You can use a business card or the like to
block the light).
(4) Loosen the lock screw of the M1 adjust lever.
(5) Looking at the G image on the screen, turn or slide the M1 adjust lever until the eclipse on the screen disappears.
Tighten up the screw.
(6) To adjust the R mirror, shield the G and B mirrors and adjust the M5 adjust lever. For the B mirror, shield the R and
G mirrors and adjust the M6 adjust lever.
(Take the same steps 4 and 5 above.)
(7) Remove all the shielding plates to have a white image.
Make sure there is no eclipse.
M4/M6
adjust lever
Lock screws
turn
Shielding plate B
FRONT
slide
Shielding plate R
Shielding plate G
24
M5
adjust lever
Lock screws
turn
slide
M1
adjust lever
turn
slide
Lock screws

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents