Belt and Belt ASY

Use abrasion counter when replacing the belt. (See Appendix)
1
Open the upper transport unit.
Unhook the two levers (green)
2
and pull them toward you.
Guide plate
WARNING
Wait at least 3 minutes after turning off the power before
replacement.
ACHTUNG
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie
mit dem Austausch beginnen.
Guide
Document sensor unit
Levers(green)
Belt ASY (inside)
While holding up the document
3
sensor remove the roller ASY.
4
Set the guides to B4 width.
Hold the guide plate at the top
5
and pull it out while pushing the
bottom in with your thumb.
Levers(green)
3-9