FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 22
EXTENSION PIPE KITS: L, M and S are designed to extend both Supply and Exhaust Pipes from the back of the
heater to the Flue Pipe which is the only approved method of transporting hot flue gasses through a wall. The
extension pipes must be installed "exposed surface mounted" within the heated room.
Extension Pipe Kit (L)
Max. 1000 mm ~ Min. 570 mm
1
(# 17206027)
Max. 1000 mm
2
(# 17206089)
Max. 2000 mm
3
(# 17206091)
Max. 1000 mm
4
(# 17206025)
No.
Name of Part
Adjustable Exhaust Pipe
1
Max. 1000 mm ~ Min. 570 mm
Exhaust Extension Pipe
2
(long, 1000 mm)
3
Intake Pipe (2000 mm)
Insulating Cloth Cover
4
(1000 mm)
5
Pipe Holder
6
Pipe Support Hardware
7
L-Shaped Exhaust Joint
When using the "Extension pipe (L)" extension kit, the distance
between the heater exhaust pipe connection and the flue pipe
connection must be at least 1620 mm but no more than 2050 mm.
(See Figure 1 above.)
"Note that Exhaust Extension Kits L, M and S are designed for
installation inside the heated room, and for exposed (surface)
mounting only".
EXTENSION PIPE KIT
PART #17206013
7
5
90 mm
(# 17187098)
(# 17212685)
6
(# 17206004)
Pipe Support Hardware
Pipe Holder (2 pcs.)
Pipe Holder Support (1 pc.)
Nut (1 pc.)
Screw
Wood Screw
(1 pc.)
(2 pcs.)
Figure 1
Q'ty
1
Flue pipe
connection
1
1
Intake
Hose
2
1620 ~ 2050 mm
2
3
sets
1
Heater
Exhaust
pipe
connection
INSTALLATION WITH EXTENSION PIPE KIT (L)
Intake Hose
Pipe
Holder
Pipe Support
Hardware
NOTE: Use "L"-shaped Exhaust Joint if necessary.
Adjustable
Exhaust Pipe
Insulation
Cloth Cover
Exhaust Extension
Pipe (long)
22