Electric Section Maintenance - LAVAZZA LB 1000 BLUE FAMILY Maintenance Manual

Table of Contents

Advertisement

A
A
C
10
D
E
"LB 1000 BLUE FAMILY"
"

Electric section maintenance

A
A
B
X
C
D
A
To replace the thermostats with the
assembled unit, beforehand disconnect them
from the 4 faston terminals "A" of the
electric system.
Caution: before performing this
operation verify that the machine is
not hot so as to avoid burning!
Keep the unit steady by hand on the point
"X" to avoid rotation, remove with the
other hand the thermostats "A" and "B"
loosening the two screws "C" by means of
8 mm hexagonal socket spanner "10",
which fix the brackets "D".
To remount the thermostat apply on the
lower side "E" coat silicone pulp to the
thermal conductivity.