D
F
G
H
C
C
B
D
7
F
"LB 1000 BLUE FAMILY"
"
Hydraulic section maintenance
E
G
B
A
D
E1
F
F1
A
6
C
Before removing the electromagnetic pumps you
have to carry out the following operations:
- disconnect the four power faston terminals
"A";
- disconnect the two coupling elbows "B" from
B
the pumps;
- disconnect the two PTFE hydraulic tubes by a
simple clockwise rotation of the three quick
couplings "C", each tube is complete of washer
"G" and joint "F";
- in this phase to replace the aspiration filter "D"
disconnect the silicone tubes "H" and "G".
To remove the pump "A" use the 12 mm
spanner "6" to clamp the pump tube "B" in
such way that it does not rotate, by means of
15 mm spanner "7" unscrew the connector "D"
with its joint "E1"; to remove the pump "C"
proceed following the above description with
the only difference that you have to unscrew
the tube union "F" by hand with its joint "F1".
Caution: to mount again the
connectors "D" - "F" it is important
to apply on it a clamping torque of
MAX 2,5 N x mt so as not to damage
them.
They have to be tightened until the ring nut
hits the tube and not more. If is possible
tighten by hand without the spanner.
6