Shuttle Stop
3.1) Fit the shuttle stop to the track at the power head
end by inserting the stop assembly into the track
and tighteneing the bolts .Do not overtighten.(Fig 8)
This will prevent the door from contacting the motor
when operatated manually.Warranty will be void if
motor is damaged due to stop not being fitted.
Terminals and Connections
1) GND & PB: Step by step command input (open
stop close) same as the step by step button on the
transmitter. = Push Button terminal
2) GND & PE = Photo Beam terminal.
3) 24V & GND & PB = Plug in receiver terminal.
To safeguard the opener and avoid damaging
components while wiring disconnect the unit from all
power when working on it.
Remember that there are specific, strict standards that
must be complied with in regard to both the safety of the
electrical systems and automatic doors.

Programming the Unit

The system must be checked and tested when
connections are completed.
4.1) Check that the chain support is halfway so that
movement is problem free both in opening and
closing.
Make sure that all the standards relative to the
automatic gates and doors category have been
observed.
4.2) Now carry out a test with the door disconnected
from the motor and open and close the door to
verify that the mechanical parts are all in good
working order and the door does not bind or jamb
in its tracks.
4.3) Power the unit. As soon as the unit is powered the
system displays a 7-segment LED number from
0-9, and the lamp will turn on for 2 seconds.
PB GND PE 24
Only qualified, trained personnel may carry out the
installation and subsequent maintenance in compliance
with Australian standards.
Whoever installs and uses the Smart Lifter sectional door
opener will be held responsible for any damage caused.
NOTE: Contact Smart Openers technical department for
the wiring diagram for the above connections if uncertain
of the correct procedure.
If the LED display is upside-down, press the SET
button once, then the LED will display the number
in the correct direction. The system will remember
the display direction. It will display correctly next
time the power is turned back on.
If this is not the case, switch the power off
immediately and check connections carefully.
4.4) Check that all the safety devices on the unit are
working properly (emergency stop, photo beam,
etc.). This is one of the most important checks and
must be done with great care; in fact, the active
safety of the automatic door depends on the correct
functioning of the safety devices. The reversing
sensitivity device is of great help in minimising
damage but only the correct installation of the
safety devices will make it possible to stop the door
before it can cause any damage or injury to person
and/or property.
4.5) It is now time to set the opening and closed
position.
-8-
Fig. 8

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart Lifter and is the answer not in the manual?

Questions and answers

Kenneth
February 7, 2025

How I can install spring for suction gate

Subscribe to Our Youtube Channel

Table of Contents

Save PDF