CARLO GAVAZZI
A u t o m a t i o n C o m p o n e n t s
M M o o t t i i o o n n R R a a d d a a r r S S e e n n s s o o r r
R R A A D D S S e e r r i i e e s s
Motion Radar Sensor is a digital uni or bidirectional
motion sensor for trouble-free opening of all types of
automatic doors (sliding, swinging, folding, revolving,
speed-doors, overhead doors, etc...), for pedestrian
and civil applications.
It can be adapted to every application without further
accessories and can be controlled by an infrared
remote controller. Mounting height up to 4m (13.12ft)
also available in uni- or bidirectional mode to detect
motion towards or away from the device. Like most of
other microwave detectors, equipped with planar flat
antenna, Carlo Gavazzi Radar activates automatic
doors utilizing doppler shift effect for detecting
movements.
L1
L2
L3
L4
L5
L6
Safety Notes
With stranded wires: all strands must be secured in
Read Instructions!
the terminal blocks (potential danger of short circuit).
Before working with this unit, read these instructions
carefully and completely. Make sure that you have
In operation: No modifications!
understood all the information!
As long as the unit is in operation: do not modify the
installation! The same applies also to the secondary
Disconnect system from supply network
side.
Before any installation, maintenance or modification
• The unit must not be opened except appropriately
work:
trained personnel!
Disconnect your system from the supply network.
• Do not introduce any object into the unit!
Ensure that cannot be re-connected inadvertently!
• Keep away from fire and water!
Before start of operation ensure appropriate
FCC warnings
installation
This device complies with Part 15 of the FCC Rules.
Warning! Improper installation / operation impair
Operation is subject to the following two conditions:
safety and result in operational difficulties or complete
1) this device may not cause harmful interference, and
failure of the unit.
2) this device must accept any interference received,
The unit must be installed and put into service
including interference that may cause undesired
appropriately by qualified personnel. Compliance with
operation.
the relevant regulations must be ensured.
© Copyright – Carlo Gavazzi - All rights reserved
This manual accompanies our equipment for use by the end users.
The technical instructions and illustrations contained in this manual are to be treated as confidential and no part
may be reproduced without the prior written permission of Carlo Gavazzi
Service engineers and end users may not divulge the information contained herein or use this manual for
purposes other than those strictly connected with correct use of the equipment.
Specifications are subject to change without notice. Pictures are just an example.
Electrical Connections
Red LED
IR Receiver
Green LED
Push Button
DEC (-)
Main Connector
Push Button
Relay NO contact
INC (+)
Relay NC contact
Relay Common
Supply Voltage
Planar
12 to 24 VAC/DC
Antenna
12 to 24 VAC/DC
Caution:
Power on the radar by Class2 or LVE transformer.
Do not power on the radar until all primary and secondary wiring is completed.
Sensing Field adjustment
Mechanical sensor orientation
Planar antenna
vertical angle
45°
Adjust the vertical position to obtain the vertical sensing field close or far from the door.
Cover Removing
Remove cover from behind, before installation.
After installation from the front side, insert the screwdriver in the provided slot.
Inside View
RAD 01 To obtain narrow pattern L2 install
RAD 01 To obtain wide pattern L1 install
the planar antenna in horizontal mode.
the planar antenna in vertical mode.
RAD 02 To obtain narrow pattern L3 or L4.
3.0
2.5
2.0
0.5
1.5
2.5
3.5
4.5
m
Planar antenna
3.0
2.5
2.0
vertical angle
0.5
1.0
1.5
2.0
2.5
15°
3.0
m
Adjust the lateral position to obtain the desired lateral angle sensing field.
Installation Tips
Fix firmly radar
Avoid the presence
sensor to the wall.
of moving objects
in radar sensing
field.
Drilling Plan mm (inches)
3.0
2.5
2.0
1.5
0.5
1.5
Mounting Instructions
2.5
Wall mounting.
3.5
4.5
m
To install radar is necessary only a screwdriver and drill.
1.5
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
3.0
2.5
2.0
1.5
Sensing field adjustment according to Sensitivity setting and mounting Height
0.5
S1
The sensing field area size (lobo) depends on the sensitivity parameter setting and the radar mounting height.
1.5
RAD 01 Bidirectional Model
S5
Detection area vs Sensitivity value (vertical angle 45°); vertical mount mode.
2.5
S8
3.5
L1
L2
3.0
2.5
2.0
1.5
S10
4.5
0.5
m
1.0
Lateral angle rotation -15°
1.5
2.0
2.5
3.0
m
Detection area vs Sensitivity value (vertical angle 45°); horizontal mount mode.
Lateral angle rotation 0°
L1
L2
L3
1.5
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
3.0
2.5
2.0
1.5
0.5
S2
S4
S6
1.5
S8
S10
2.5
3.5
3.0
2.5
2.0
1.5
Lateral angle rotation 15°
4.5
0.5
m
1.0
1.5
2.0
m
Detection Area Shape modifying instructions
To adjust the type of the sensing field and pattern, verify the following instructions:
RAD 01 To obtain wide pattern install the planar antenna in vertical mode, while to obtain narrow pattern
install the planar antenna in horizontal mode. Carefully remove the fixing tie clip with a screwdriver
and change the orientation mode of planar antenna.
Not install panels or
Not install radar
Not install radar
metallic
surfaces
on direct exposure
close to fluorescent
close to the device.
of rain.
lamp.
1
Ceiling
100 (3.937")
Ø 3 (1/8")
Ø 3 (1/8")
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
3.0
2.5
2.0
1.5
1.0
Ø 8 (5/16")
Cable inlet
0.5
S1
13
(0.511")
1.5
S5
2.5
S8
Ceiling mounting.
3.5
S10
4.5
m
4
CAUTION!
Power off the radar before removing the planar antenna.
The radar is an electrostatic sensitive device: proceed with caution to remove the planar antenna,
don't wear synthetic clothes or rubber sole shoes.
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
S1
RAD 02 Uni & Bidirectional Model
S5
Detection area vs Sensitivity value (vertical angle 15°).
S8
S10
L3
L1
L4
L2
L5
L3
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
3.0
2.5
2.0
1.5
1.0
0.5
S2
S4
S6
1.5
S8
S10
2.5
h = 2.2m
h = 7.22ft
3.5
4.5
m
Detection area vs Sensitivity value (vertical angle 45°).
L1
L4
L2
L5
L3
L6
L4
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
S4
S6
h = 2.2m
h = 7.22ft
S8
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
3.0
2.5
2.0
1.5
1.0
S10
S1
S9
0.5
S5
S10
1.0
S10
1.5
Note: S1...S10 sensitivity levels setting.
2.0
m
1.5
S5
2.5
S8
3.5
S10
4.5
m
2
0.5
0 0.5
3.0
2.5
1.0
2.0
1.5
1.5
2.0
1.0
2.5
0.5
3.0
0 0.5
m
1.0
1.5
2.0
2.5
3.0
m
0.5
S2
S1
1.0
S4
S6
1.5
S8
3
S5
2.0
S10
2.5
S8
3.0
S10
m
5
L6
L4
L5
L6
0.5
0 0.5
3.0
2.5
1.0
2.0
1.5
1.5
2.0
1.0
2.5
0.5
3.0
0 0.5
m
1.0
1.5
2.0
2.5
3.0
m
S1
0.5
S5
S4
1.0
S10
1.5
2.0
m
S6
h = 2.2m
h = 7.22ft
S8
S10
L5
L6
3.0
2.5
2.0
1.5
1.0
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
0.5
S1
1.5
S5
2.5
S8
h = 2.2m
h = 7.22ft
3.5
0.5
0 0.5
1.0
1.5
2.0
2.5
3.0
m
S10
S1
4.5
S8
m
1.5
2.5
3.5
4.5
m
3.
0.5
1.5
2.5
3.5
4.5
m
3.
0.5
1.0
1.5
2.0
m
3.0
0.5
1.5
2.5
3.5
4.5
m
Need help?
Do you have a question about the RAD Series and is the answer not in the manual?
Questions and answers