CARLO GAVAZZI LDP2PA2BU24-7 Instruction Manual
CARLO GAVAZZI LDP2PA2BU24-7 Instruction Manual

CARLO GAVAZZI LDP2PA2BU24-7 Instruction Manual

Loop detector dual loop plug in

Advertisement

Quick Links

Loop Detector
Dual Loop
Plug In
LDP2PA2BU24-7
LDP2PA2BU24-8
Instruction manual
Carlo Gavazzi Industri Over Hadstenvej 40, 8340 Hadsten, Denmark

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDP2PA2BU24-7 and is the answer not in the manual?

Questions and answers

Summary of Contents for CARLO GAVAZZI LDP2PA2BU24-7

  • Page 1 Loop Detector Dual Loop Plug In LDP2PA2BU24-7 LDP2PA2BU24-8 Instruction manual Carlo Gavazzi Industri Over Hadstenvej 40, 8340 Hadsten, Denmark...
  • Page 2: Table Of Contents

    8. Product Setup Guide ....................17 8.1 Channel Selection ......................17 8.2 Sensitivity adjustment ......................18 8.3 Automatic Sensitivity Boost (ASB) ..................19 8.4 Fail Safe and Fail Secure mode ....................20 Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 3: Introduction

    Low Voltage (2014/35/EU) and Electromagnetic Compatibility (2014/30/EU) EC directives. All rights to this document are reserved by Carlo Gavazzi Industri: copies may be made for internal use only. Please do not hesitate informing us to make any suggestions for improving this document.
  • Page 4: Product

    Code Option Description Loop Detector Plug in Dual loop Potentiometer Adjustment Number of outputs 2 x SPST outputs Power supply 24 - 240 VAC/VDC Special number Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 5: Specifications

    Connection at socket (ZPD11A) Screw terminal Housing material PPO PX9406-802, PPO Noryl SE1 Colour RAL 7035 (Grey) Dimensions 81mm (h) x 35.5mm (w) x 60.2mm (d) Weight 108 g Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 6: Wiring Diagrams

    3. Wiring diagrams LDP2PA2BU24-7/8 required to be plugged into a socket ZPD11A or equivalent which is sold separately. LDP2PA2BU24-7/8 plug configuration Supply Supply Loop 1 Loop 1 Loop 2 Loop 2 Relay 2 Normally Open (NO) Relay 2 Common (COM)
  • Page 7: Led Indications

    LED OFF LED ON Pulse mode, 0.1 s LED OFF LED ON for 0.5 s Pulse mode, 0.5 s LED OFF LED ON for 1.0 s Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 8: Power / Fault Indicator Led

    • Yellow LED (on for 0.5 s): Relay is activated and in pulse mode, 0.1 s • Yellow LED (on for 1.0 s): Relay is activated and in pulse mode, 0.5 s Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 9: Dip Switch

    • When DIP SWITCH 1 is set to ON, the user manually selects which channel is used by setting DIP switch 2 and 3. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 10 Normally Open (NO) contact will become a Normally Closed (NC) contact and the Normally Closed (NC) contact will become a Normally Open (NO) contact. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 11 Note: DIP switch 10 will have different functionality depending if product is set to operate in Pulse or Presence mode on DIP switch 9. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 12 1 and relay 2 will activate when a vehicle is detected in loop 2. Direction Relay 1 Loop 1 Loop 2 Direction Relay 2 Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 13: Loop Installation

    The width of the loop should therefore aim to have same dimension as the vehicles which needs to be detected. Track width Favourable Unfavourable Unfavourable Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 14: Inductance And Loop Turns

    15 - 23 meter (49.2 - 75.5 feet) 24 - 30 meter (78.7 - 98.4 feet) Loop circumference = 2 x a + 2 x b. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 15: Loop Wire Material

    Conclusion 100 to 1000 MΩ Loop condition is good 50 to 100 MΩ Loop integrity is questionable 0 to 50 MΩ Loop needs to be replaced Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 16: Feeder Cable

    Movement of the feeder cable during operation can lead to false detections. • Feeder wires from adjacent Loop Detectors, should not be placed in close proximity of each other. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 17: Ground Installation

    This is ensured by the product design. LDP2 Loop Trafic flow Channel 1 Loop Channel 2 Loop Channel 1 LDP2 Loop Trafic flow Channel 2 Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 18: Sensitivity Adjustment

    CAUTION: It is important to carefully test the application before the system is put into operation. Setting the sensitivity too high or too low, can lead to unexpected behaviour of the application. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 19: Automatic Sensitivity Boost (Asb)

    Note: It is generally recommended to only use the ASB function for applications where high bed vehicles needs to be detected. For detection of passenger cars, vans etc. best detection is usually achieved with ASB OFF. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 20: Fail Safe And Fail Secure Mode

    Note: If power is returned to the product while a vehicle car is parked on top of the loop, the Loop Detector will not activate. Only a new vehicle entry will generate an activation. Rev.00 - 03.2019 | LDP2PA2BU24-7-8 Loop Detector | © 2019 | CARLO GAVAZZI Industri...
  • Page 21 CARLO GAVAZZI www.gavazziautomation.com Certified in accordance with ISO 9001 LDP2PA2BU24-7/8 Loop Detector ENG rev.00 - 03.2019...

This manual is also suitable for:

Ldp2pa2bu24-8