Car park system ultrasonic sensor

Advertisement

Quick Links

Fig. 3 - Example of Connection
GP6240 2224 724-US
Programmable connector
for GP 7380 0080
D+ D-
Pow
Pow
D-
D+
X
Y
Fig. 1
Fig. 1
Parking bay
Parking bay
Parking bay
Sensor 1
Sensor 2
Sensor 3
LED indicator
LED indicator
(Optional)
Lane
Fig. 2
Fig. 2
Parking bay
Parking bay
Parking bay
Sensor 1
Sensor 2
Sensor 3
Fig. 2
Parking bay
Parking bay
Parking bay
Parking bay
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Status address
Status address
Status address
Status address
B1
B2
B3
B4
Lane senor
Lane
Lane sensor
Lane
Dimensions
118 mm
Locally push button for calibration
Bottom Part: Ceiling Mounting
Sensor Placing
The sensor is designed to work in an area which is:
Max. 4 m
Min. 1.5 m
The sensor will not react to objects lower than 0.3 m.
Sensoren reagerer ikke på emner mindre end 0,8 m.
Parking bay
Sensor 5
The sensor should be placed freely, e.g. in the following way:
Status address
B5
Sensor
Sensor
LED indicator
LED indicator
(Optional)
Ceiling beam
Loftbjælke
A = Min. 20 cm between ceiling beams
A = Min. 2 meter mellem loftbjælker
B = Max. 65 cm high ceiling beams
B = Max. 50 cm høje loftbjælker
76 mm
To receive the best signal, the sensor must be installed with an angle
on the ceiling of maximum ±5°.
2.0 m
2,5 m
4 m
The sensor can operate in a 4 m long and 2.0 m wide parking bay
Sensoren kan operere i 4 m lang og 2,5 m bred parkeringsplads
GP6289 000x-US
Not in use
X
Y
0.3 meter
0,8 meter
B
A
MAX ±5°
Parkingplaces
Parkeringspladser
Dupline
Car Park System
®
Ultrasonic Sensor
Type GP62xxxxxx724-US
User Manual
CARLO GAVAZZI
www.gavazziautomation.com
Certified in accordance with ISO 9001
MAN GP62xxxxxx724-US rev. 03 - 09.2014

Advertisement

loading
Need help?

Need help?

Do you have a question about the Dupline GP62 724-US Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CARLO GAVAZZI Dupline GP62 724-US Series

  • Page 1 B = Max. 65 cm high ceiling beams B = Max. 50 cm høje loftbjælker Dimensions 118 mm 76 mm CARLO GAVAZZI MAX ±5° www.gavazziautomation.com To receive the best signal, the sensor must be installed with an angle on the ceiling of maximum ±5°.
  • Page 2 Type Selection Mode of Operation Programming the sensor GP6220 2201 724-US Sensor with green/red LED The ceramic sensor emits an acoustic signal at a frequency of 40 The programming of the GP62xxxxxx724-US is described in GP6220 2202 724-US Sensor with blue/red LED kHz which is reflected when it hits the floor and returned to the the “Carpark Design and Installation Guide”.

This manual is also suitable for:

Dupline gp6220 2201 724-usDupline gp6220 2202 724-usDupline gp6240 2224 724-us