Room Heating Capacity; Approved Fuel Types; Fuel Quantities; Regulating The Combustion Air - Drooff elba Installation And Operation Manual

Table of Contents

Advertisement

T E C H N ICA L INFOR M ATI O N
ROOM-hEATInG CAPACITy
Room-heating capacity in m
Heat requirement
According to DIN 18893, the above mentioned room volumes apply for rooms which do not
comply with the legislation on thermal insulation. Lower capacities are sufficient for rooms
of the above volumes which comply with the legislation on thermal insulation.

APPROvED FUEl TyPES

n Dry untreated logs with a maximum residual moisture content of 19% measuring 30 cm
(max.) in length and approx. 10 cm in diameter.
n Wood briquettes
n Lignite briquettes

FUEl QUAnTITIES

Quantity
For 4 kW approx.:
Per stoke approx.:
For 8 kW approx.:
Per stoke approx.:
Depending on the quality of the fuel, the chimney and the weather conditions, it will take
approx. 30-45 minutes for one stoking of fuel to burn down. When it has burned down to the
red embers, the stove can be re-stoked.
REGUlATInG ThE AIR InFEED
Secondary air (marked P)
Open = slide knob at I
Closed = slide knob at 0
Primary air (marked S)
Open = slide knob at I
Closed = slide knob at 0
Feuer aus dem Sauerland
DROOFF Kaminöfen —
3
suitable
less suitable
unsuitable
logs
Wood Briquettes lignite Briquettes
1.0 kg /h
1.0 kg/h
0.8 kg
0.8 kg
2.1 kg /h
2.1 kg/h
1.6 kg
1.6 kg
4 kW
8 kW
62
182
39
105
25
71
-
-
1.7 kg /h
1.7 kg
Air valves
Page 21
w w w . d r o o f f - k a m i n o f e n . d e

Advertisement