Distance To Combustible Materials - Drooff elba Installation And Operation Manual

Table of Contents

Advertisement

T E C H N ICA L INFOR M ATI O N
Performance parameters
Rated thermal output in kW
Thermal output range in kW
Exhaust gas mass flow in g / s
Temp. at chimney sleeve in °C
Suction pressure in mbar
CO emission in mg / Nm
3
Dust emission in mg/Nm
3
Efficiency in %
(All data is laboratory data)

DISTAnCE TO COMBUSTIBlE MATERIAlS

Safety clearance to inflammable materials/partition walls
Rear
Side
Front
For your own safety it is essential to observe the above distances between the stove and
combustible or valuable objects e.g. furniture, panelling, wood etc. as well as structural walls
of steel reinforced concrete. The distance between the stove and non-combustible materials
or objects may be slightly less. These clearances are required for compliance with the
regulations applicable in Germany for fireplaces, stoves and other heating appliances.
In spite of compliance with the above safety clearances, the stove may cause discolouration
of sensitive materials in its vicinity e.g. wallpapers containing vinyl, textile or other structuring
substances. These discolourations are due to the quality of the materials and are not covered
by the guarantee. The specified safety clearances between the stove and inflammable or
valuable objects are intended only to prevent the outbreak of fire.
Feuer aus dem Sauerland
DROOFF Kaminöfen —
logs/ Wood briquette
4.0
8.0
3 - 10
3.6
6.2
300
330
0.12 min.
0.12 min.
0.20 max.
0.20 max.
1250.0
1250.0
< 40.0
82.5
82.9
15 cm
20 cm
85 cm
lignite briquettes
8.0
3 - 10
7.0
345
0.12 min.
0.20 max.
2000.0
< 40.0
78.9
Page 19
w w w . d r o o f f - k a m i n o f e n . d e
Position near wall
Back wall
20 cm
85 cm
Corner position
Back wall
15 cm
15 cm

Advertisement