8.2. Calibration procedure
The Orion³² can be calibrated periodically in order to calibrate the accuracy of the internal clock
by connecting it to the 10M Atomic Clock. This procedure is not typically required often, but when
necessary, please follow these instructions:
● Connect the 10M to Orion³² via the dedicated 10M input;
● Power on the 10M and wait until it reaches operating temperature;
● With the Orion³² in standby mode, press and hold the Antelope button whilst pressing Preset
button 2;
● Leave the buttons and wait for one minute to allow the units to stabilize;
● You will see "Calibration" appear on the display along with "Heating Up" and the temperature
of the Oven;
● Wait for the calibration to take place;
● When the Err. Number becomes stable, press the Preset button 2 again to end the
calibration;
● You will see "DONE" displayed on the LCD screen.
9. Additional Information
Additional information regarding operating systems, audio software and media players will be
updated through the support area at www.antelopeaudio.com.
10. In the box
● Orion³² Multi-Channel AD/DA Converter
● Owner's Manual
● Warranty card
● Power cable
● USB cable
11. Technical Specifications
Inputs
Analog Inputs
Digital Inputs
4 x D-SUB 25 (32 channels), +20 dBu max, 11.2 kOhms
1 x Fiber Optic MADI
2 x ADAT
1 x S/PDIF