Download Print this page

Advertisement

Instructions for use and installation
Cooker Hood
FTU 3807 WXS 70H
FTU 3807-P WXS 70H

Advertisement

loading
Need help?

Need help?

Do you have a question about the FTU 3807 WXS 70H and is the answer not in the manual?

Questions and answers

Summary of Contents for Franke FTU 3807 WXS 70H

  • Page 1 Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807-P WXS 70H...
  • Page 2: Table Of Contents

    Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS ........................18 CHARACTERISTICS................................19 INSTALLATION ..................................20 USE.......................................24 MAINTENANCE..................................25...
  • Page 3: Recommendations And Suggestions

    RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • Page 4: Characteristics

    CHARACTERISTICS Dimensions Components Ref. Q.ty Product components Hood equipped with: Controls, Lights, Filters Hood support equipped with the Exhaust Group tube in PVC Directioned grid Air outlet reduction ø 120mm Reduction flange ø 150-120 mm Ref. Q.ty Installation components Small blocks ø 10 Screws 5 x 70 Screws M4 x 15 Screws 2,9 x 9,5...
  • Page 5: Installation

    INSTALLATION Wall drilling and bracket fixing Due to the complexity in installing the hood, we suggest to do it minimum in two people 100 100 When installing the hood in recycling version it has to be taken into consideration that space re- maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm.
  • Page 6 Hood support mounting • Lean the hood support 3 against the wall making sure that holes in the hood support correspond to those in the wall. • Block the hood support to the wall using 4 12a (5 x 70) screws supplied with the hood.
  • Page 7 ø 150 RECIRCULATION VERSION AIR OUTLET • Insert pvc pipe 7 provided onto the Hood Canopy Outlet. Hood body mounting Ducting version • In case the air outlet connection on the upper part of the hood has been chosen it will be necessary to remove the pre-cut piece.
  • Page 8 ELECTRICAL CONNECTION • Connect the hood to the mains through a twopole switch having a contact gap of at least 3 mm. • Open the lighting unit by pulling on the notch. • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Page 9: Use

    Control board Function Display Switches the extractor motor on and off at the Indicates the selected speed. latest selected speed Decreases the suction speed. Increases the suction speed. By pressing this key it is possible to activate HI appears. The spot down on the right side the intensive speed from any previously se- flashes once a second.
  • Page 10: Maintenance

    MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type. • Do not place the remote control near to heat sources. • Used batteries must be disposed of in the proper manner. Cleaning the Comfort Panels •...
  • Page 11 Metal grease filters Filters can be washed in the dish machine. They need to be washed when FF-sign appears on the display or in any case every 2 months, or even more frequently in case of particularly intensive use of the hood. Alarm reset •...
  • Page 12 Charcoal filter (recycling version) • This filter cannot be washed or regenerated. It must be replaced when the EF appears on the display or at least once every 4 months. Activation of the alarm signal • In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.

This manual is also suitable for:

Ftu 3807 w xs - in2