Cover Removal
1
You have now installed the Programmable Thermostat. For gas boiler applications, the factory system settings will not
need to be changed (for other applications see below). You can now use the USER GUIDE to program the unit and
demonstrate how it works to the homeowner.
Using the Programmable Thermostat for Specific Applications
Application
Cycle /Hour
Gas Boiler (<30kW)
6
Oil Boiler
3
Thermal Actuator
12
Zone Valve
6
Electric Heating
12
(resistive load 3-5A)
Entering the Installer Mode
1. Press the OFF button.
2. Press and hold the
button and the two PROGRAM
and
buttons together.
3. The unit will display the first parameter of installer
parameter group category 1 (from Parameter No. 1 to
20).
4. Press the
or
button to change the factory
setting. The display will flash indicating that a change
has been made.
5. Press the
button to confirm the change. The display
will stop flashing.
6. Press the
button to go to the next parameter.
7. Press the PROGRAM
button to go to Installer
parameter group category 2 (from Parameter No. 1 to 5).
8. To exit installer mode, press the AUTO, MAN or OFF
button.
2
Located
at base
of battery
enclosure
Settings
Minimum ON time
1
4
1
1
1
What to change
Note: All parameters listed below belong to category 2
– system parameters (see Installer Parameter Table)
No changes required
Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
Set 2:Cr parameter to 12
No changes required
Set 2:Cr parameter to 12
Mon
Tue
Wed
Thu
Fri
Sat
DATE/
DAY
MANAUTO
COPY
DAY
PROGRAM
1..4
Mon
Tue
Wed
Thu
Fri
Sat
DATE/
DAY
COPY
DAY
1 2
PROGRAM
1..4
2
3
Sun
AUTO
MAN
1
OFF
Sun
AUTO
MAN
2
OFF

Advertisement