Page 1
ANUAL RIOR NSTALLATION PERATION PPLIANCE LEASE HESE NSTRUCTIONS UTURE EFERENCE Manufactured By Blaze King Valley Comfort Systems Inc. Blaze King Industries 1290 Commercial Way 146 A Street Penticton, BC V2A 3H5 Walla Walla, WA 99362 ISTED CANADA U.S.A. Phone: (250) 493-7444...
Page 2
While we have made every effort to make these instructions as complete as possible, some installation or operating conditions may not be covered. If you have any questions that are not answered here, contact your BLAZE KING dealer, Local Building Inspector, Fire Department, or our customer service department.
RESPONSIBILITIES OF THE COMPANY: If the purchaser has complied with all of the terms and conditions of this warranty and if the purchaser has notified Blaze King of a defect prior to the expiration of the respective warranty period and after shipment, Blaze King will either repair or replace the product, AT ITS ELECTION, or MAY ELECT to refund a portion of the purchase price, based on the formula below, if it cannot readily and quickly provide the purchaser with a replacement.
CERTIFIED IN BOTH UNITED STATES AND CANADA PREVENT HOUSE FIRES- Install and use only in accordance with Blaze King’s installation and operation instructions. Install and use in a code complying fireplace only. Stainless steel flue liner is required in Canada and recommended in the United States. Contact local building or fire officials about restrictions and installation inspection in your area.
General Information—Safety BRIARWOOD Model BRII/90 - Fireplace Insert Residential Approved Briarwood Room Heaters have been developed, tested and constructed in accordance with the requirements of UL 1482-1998 / ULC S628-M93. Safety testing was performed by Intertek Testing Services laboratories. These units are designed as safe and efficient, solid fuel burning heaters, but they must be installed and operated properly.
Page 7
(see figure to the right). 36. SAVE THESE INSTRUCTIONS. Fireplace Opening THE INFORMATION CONTAINED HEREIN IS BELIEVED TO BE ACCURATE. HOWEVER, NO RESPONSIBILITY FOR ERRORS OR OMMISIONS IS ASSUMED BY BLAZE KING INC. OM-BRII/90I.PUB Page 7 Version 1.01 Printed: May 25, 2011...
Do not slam the loading door or otherwise impact the glass. If the glass gets cracked or broken, it must be replaced before using the stove. Replacement parts can be obtained from your authorized Blaze King dealer. The glass is a 5mm high temperature ceramic.
Installation—Location & Clearances YOUR STOVE'S LOCATION 1. Plan ahead to be certain that furniture, drapes and curtains cannot come within the combustible clearances listed on the table below. 2. Refer to the approval label on the stove for correct clearances to combustibles. 3.
Installation—General BRIARWOOD II INSERT STOVE INSTALLATION PROCEDURE AFTER YOU READ AND FULLY UNDERSTAND THE MATERIAL IN THIS MANUAL, YOU ARE READY TO PROCEED WITH THE INSTALLATION OF YOUR STOVE. SAFETY NOTICE: IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
Installation—General INSTALLATION INTO FACTORY BUILT FIREPLACES In addition to the general instructions presented throughout the manual you must take care to ensure the following steps are correct when installing this insert into a factory built fireplace. 1) The factory built fireplace must be listed per UL127 or UL S620. 2) All clearances to combustibles must be maintained as shown on the label.
Installation—Chimney CHIMNEYS: GENERAL Refer to the chimney and chimney connector manufacturer’s instructions for additional information. If this stove and its chimney components are not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation requirements in your area.
Operation—General ANDIRONS OR GRATES - (Not For Use On The Briarwood Insert) Briarwood Stoves are designed for the burning of wood directly on the firebrick. Highest efficiencies and burn characteristics are obtained when a half-inch bed of ashes is maintained in the firebox. STARTING YOUR FIRST FIRE (Curing Your Stove Paint) Curing your stove will give off fumes so make sure you provide extra ventilation by opening a door or window during the curing process.
13] If you have not purchased the optional fans you must now install the fan housing pieces (fig. 1). The housing attaches with 2 screws top & bottom with the large round hole facing out. 14] Blaze King strongly recommends that you install a complete Stainless Steel flue liner system. This is the safest installation and will ensure proper draft control for best burn conditions and consistency.
Assembly—General / Optional OPTIONAL INSTALLATION INSTRUCTIONS Optional Gold Trim Installation: Assemble the trim strips as shown in (fig 12) and attach to the shroud outer edge using the screws provided. Return to step 4 and continue the installation. Optional Fans Installation: (Note: The following instructions pertain to both fans on the left and right sides of the stove.) 1.