Operation; Cleaning And Maintenance - Omnitronic PAP-350 Instruction Manual

Pa amplifier
Hide thumbs Also See for PAP-350:
Table of Contents

Advertisement

Available languages

Available languages

If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Calculation number of speakers – impedance
E.g. 1 speaker à 8 Ohm = 8 Ohm
2 speakers à 8 Ohm = 4 Ohm (parallel)
2 speakers à 8 Ohm = 16 Ohm (in line)
3 speakers à 8 Ohm = 2.66 Ohm (parallel), only for amplifiers capable of handling 2 Ohms
2 speakers à 8 Ohm = 24 Ohm (in line)
4 speakers à 8 Ohm = 2 Ohm (parallel), only for amplifiers capable of handling 2 Ohms
N.B.:
The input-impedance of the speaker-systems should at least be the same or even higher than the output-
impedance of the amplifier.

OPERATION

After having connected your amplifier to the mains, turn the volume control counter-clockwise to Min-
position. The last device to be switched on is the amplifier. Adjust the volume with the volume control.
Caution! Increase the level of each channel only so far that the CLIP-LED lights up shortly. Thus, you avoid
that the output signal is distorted and your speakers are damaged.
When operating the speaker-system, please make sure that the loudspeakers always sound well. When
distortions can be heard, either the amplifier or the loudspeaker is overloaded. Overloads can quickly lead to
amplifier or speaker damage.
In order to avoid damage, please reduce the volume immediately when distortions can be heard. When
speaker-systems are destroyed by overload, the guarantee becomes void.
Always check the sound pressure level with a meter in order to keep to the threshold.
If you want to switch off the system, switch off the amplifier first and then the pre-amplifiers in order to
avoid acoustic shocks on the speakers.

CLEANING AND MAINTENANCE

DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
22/23
PAP_SERIES_V_1_0.DOC