iNFrArED PArAFFiN / KErOSENE / DiESEL HEATEr 70000BTU 230v
thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE rEAD THESE iNSTrUCTiONS CArEFULLY. NOTE THE SAFE OPErATiONAL rEQUirEMENTS, WArNiNGS AND
CAUTiONS. USE THE PrODUCT COrrECTLY AND WiTH CArE FOr THE PUrPOSE FOr WHiCH iT iS iNTENDED. FAiLUrE TO DO SO MAY
CAUSE DAMAGE AND/Or PErSONAL iNJUrY AND WiLL iNvALiDATE THE WArrANTY. PLEASE KEEP iNSTrUCTiONS SAFE FOr FUTUrE
USE.
1. SAFETY iNSTrUCTiONS
1.1
ELECTriCAL SAFETY
 WArNiNG! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current
device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected
by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1
the Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance tester (PAt), at least once a year.
1.1.2
the Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. if in any doubt about electrical safety, contact a qualified electrician.
1.1.3
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.
and use a Portable Appliance tester.
1.1.4
ensure that cables are always protected against short circuit and overload.
1.1.5
regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none are loose.
1.1.6
important: ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7
DO NOT pull or carry the appliance by the power cable.
1.1.8
DO NOT pull the plug from the socket by the cable.
1.1.9
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When an AstA/Bs approved uK
3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GrEEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BrOWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that
the restraint is tight.
double insulated products, which are always marked with this symbol
to rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10 If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance
plugged into it will be protected. the cable core section is important and should be at least 1.5mm
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
2
of 2.5mm
section cable.
1.2
GENErAL SAFETY
DANGEr! risk of carbon monoxide poisoning. failure to provide proper ventilation could result in serious illness or death.
 check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
 use recommended parts only. Unapproved parts may be dangerous and will invalidate the warranty.
 only use paraffin or diesel to fuel your heater, in accordance with instructions contained in this manual.
 WArNiNG! only use heater in well ventilated areas. ensure continuous ventilation from outside of the building is provided to the heater
operating area.
 Keep the front of the heater a minimum of 2.4m (8ft) from any combustible materials (i.e. wooden items, cloth, plastics, paper, etc).
 only operate on a level and stable surface.
 WArNiNG! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders.
 DO NOT use the heater in closed rooms, living areas, basements or below ground level.
 DO NOT allow untrained persons to operate the heater and DO NOT operate the heater without the cover.
 DO NOT move or handle the heater when hot.
 DO NOT leave the heater unattended when in use. switch the heater off and unplug from the mains before leaving work area.
 DO NOT fill the fuel tank whilst the heater is running or still hot.
 DO NOT over-fill the fuel container. Wipe up any spilt fuel immediately.
 DO NOT obstruct the air inlet (rear) and air outlet (front) of the heater.
 DO NOT use duct work in front or at the rear of the heater.
 DO NOT allow children or animals near the heater when in use, or while hot.
 WArNiNG! riSK OF ELECTriC SHOCK. DO NOT expose the heater to water spray, rain, dripping water or wind.
 DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
 DO NOT touch the heater outlet or dome when first switched off as these are very hot and will take time to cool.
 ensure that the heater is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
 DO NOT unplug the heater to switch it off. use the on/off switch.
InstructIons for:
model no:
, are fitted with live (brown) and neutral (blue) wires only.
Original Language Version
ir20.v2
Yellow & Green
Earth Wire
Blue
Neutral
Wire
FUSE
rATiNG 5 AMP
2
, but to be absolutely sure that the
Ir20.V2
Issue: 1 - 10/06/10
Brown
Live
Wire
Cable
Restraint

Advertisement

loading

Summary of Contents for Sealey ir20.v2

  • Page 1 PArAFFiN / KErOSENE / DiESEL HEATEr 70000BTU 230v thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
  • Page 2: Introduction And Specifications

    Fig.1 unpack the heater and check contents. should there be any damaged or missing parts contact your sealey dealer immediately. Attach handle by lining up the holes in the handle with the holes in the upper shell of the heater (fig.1).
  • Page 3: Operating Conditions

    WArNiNG! UNPLUGGiNG THE UNiT BEFOrE THE COOLiNG CYCLE HAS ENDED MAY CAUSE OvErHEATiNG, POSSiBLE  DAMAGE TO THE HEATEr AND WiLL vOiD THE WArrANTY. TO rE-STArT THE HEATEr 5.3.1 turn the Power switch to "on" position. 5.3.2 Be sure to follow all starting procedure precautions. Original Language Version Ir20.V2 Issue: 1 - 10/06/10...
  • Page 4: Maintenance

    WARNING! unplug unit from mains power supply before opening or servicing  heater. see section 1 regarding electrical safety and maintenance. Use only genuine Sealey replacement parts. The use of alternate or third party components can cause unsafe operating conditions and will void the warranty. recommended maintenance schedule: FUEL TANK flush every 200 hours of operation or as needed.
  • Page 5: Troubleshooting

    WArrANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. iNFOrMATiON: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...