Download Print this page
Sealey IR19 Instruction Manual

Sealey IR19 Instruction Manual

19kw industrial infrared diesel heater

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
1.
SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
9
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products.
Electrical safety information. It is important that the following information is read and understood:
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is replaced immediately by a
8
qualified electrician.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY
WARNING! THIS HEATER IS FOR PROFESSIONAL USE. IT HAS BEEN CAREFULLY DESIGNED FOR MOBILE AND
TEMPORARY PROFESSIONAL APPLICATIONS.
IT HAS NOT BEEN DESIGNED FOR DOMESTIC USE NOR FOR COMFORT HEATING AND SHOULD NEVER BE USED TO HEAT
CLOSED ROOMS WITHOUT ADEQUATE VENTILATION.
WARNING! This product is only suitable for well insulated spaces or occasional use.
DANGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use diesel to fuel this heater, in accordance with instructions contained in this manual.
9
Locate heater on a level and stable surface.
9
Only use heater in well ventilated areas. Ensure continuous ventilation is provided to the heater operating area via windows and
doors etc. If people are not required to be present in the heated area, the volume of air to be heated (m³)/heat output kW) ratio must
be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If people are required to be
present in the heated area, the volume of air to be heated (m³)/heat output (kW) ratio must be at least 30:1. Ventilation must be to
the outside of the premises in which the heater is to be operated. The total open area (m²) must be at least 0.003 times the total heat
output (kW). The volume concentration of oxygen (O
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 3m from any walls or
8
objects.
DO NOT use the heater in closed rooms, living areas, basements or below ground level.
8
DO NOT allow untrained persons to operate the heater and DO NOT operate the heater without the safety guard.
8
DO NOT move or handle the heater when hot, without wearing protective gloves. Never move the heater whilst it is operating.
8
DO NOT leave the heater unattended for prolonged periods of time when in use. Switch the heater off and unplug from the mains
8
before leaving work area.
DO NOT fill the fuel tank whilst the heater is running or still hot. DO NOT over-fill the fuel container. Wipe up any spilt fuel
8
immediately.
DO NOT obstruct the air inlet (rear) and air outlet (front) of the heater and DO NOT use duct work in front or at the rear of the heater.
8
DO NOT allow children or animals near the heater when in use, or whilst still hot.
8
WARNING! RISK OF ELECTRIC SHOCK. DO NOT expose the heater to water spray, rain, dripping water or wind.
DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT touch the heater outlet or cone when in use, or for a period of time after it's switched off, as these are VERY hot and will
8
take time to cool down.
© Jack Sealey Limited
19KW INDUSTRIAL INFRARED DIESEL
HEATER
MODEL NO:
Always unplug
Warning:
before servicing
Hot surfaces
and checking
) in the heated room, must always remain above 17%.
²
Original Language Version
IR19
Do not cover
Keep in dry area
protect from rain
Use in well
ventilated areas
IR19
Issue 3
08/07/24

Advertisement

loading
Need help?

Need help?

Do you have a question about the IR19 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sealey IR19

  • Page 1 IR19 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    Transport Wheels: Heated Area: 14,740ft³(450m³) Nominal Heat Output: 20kW Motor Power: Energy Efficiency Index: Noise Level: 48dB(A) Useful Energy Efficiency at Nominal Heat Output: 88.85% Weight: 60kg η (nom): Original Language Version © Jack Sealey Limited IR19 Issue 3 08/07/24...
  • Page 3: Black Smoke

    2. Adjust the air suction hole. Increase inlet ring size, increases the air intake. Proper installation of Wrong installation of smoke exhaust pipe smoke exhaust pipe Inlet rings x 6 IR19 Issue 3 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 4: Operation

    ) for 3 seconds to turn off the timer. 5.5. CHILD LOCK 5.5.1. Press the child lock button (fig.1.7 ) for 3 seconds to turn on or turn off the child lock function. Original Language Version © Jack Sealey Limited IR19 Issue 3 08/07/24...
  • Page 5: Maintenance

    6.6. CHANGE OF COMPONENTS 6.6.1. For any change of components please contact Sealey Service Centre. DO NOT try to repair the heater. Contact the place of purchase, or contact Sealey Service Centre. 6.7. FILTERS 6.7.1. The fuel filter and oil filter should be cleaned at least twice per heating season by rinsing it in clean paraffin or diesel. Contaminated or old fuel could make cleaning necessary immediately.
  • Page 6: Troubleshooting

    In case of low voltage.. Burner will not work properly, so use a booster to elevate voltage. (A/S) Please check before you think there may be a problem with the heater. IR19 Issue 3 08/07/24 Original Language Version © Jack Sealey Limited...
  • Page 7: Wiring Diagram

    IMPORTANT: No Liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 36 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk...
  • Page 8 Product Information Sheet. Local Space Heaters, Gas / Liquid Fuel. SUPPLIER_NAME_OR_TRADEMARK Sealey EU Ltd. DELEGATED_ACT 2015/1188/EU MODEL_IDENTIFIER IR19 #N/A ADDRESS Farney Street, Carrickmacross, Co. Monaghan, A81 PK68 Ireland PHONE_NUMBER 01284 757 500 EMAIL_ADDRESS TechnicalCompliance@sealey.co.uk Indirect heating functionality Direct heat output (kW) 20.0...