Seismic Restraint

All installation scenarios for Amalfi require the use of hold-down anchors (one on each side).
Fixing to Concrete Floor:
Minimum M8 expansion anchors (M10 recommended) or min M8 epoxy- set anchors.
Approved Anchors: Expansion Anchors-Ramset Dynabolt and Trubolt, Hilti HAS.
Epoxy-set Anchors – Ramset Epcon, Ramset Chemset and Hilti HVU.
2.11

Fixing to Timber Floor Framing

Minimum 14g x 60 screws (6.3mm diameter) or M10 X 90 coach-screws. These shall be fixed a minimum
of 40mm into the centre-line of the existing floor joists. If screws cannot be installed directly into an
existing floor joist, solid blocking between joists (min size 90x45) shall be provided.