EXTERNAL THERMOSTAT PROCEDURE
If an external thermostat is used, correctly connected to the mother board as shown in the electrical
circuit diagram, the message T ON will be shown on the display instead of room temperature. Room
temperature will be adjusted directly by the thermostat mounted on the wall. When the temperature
shown on the display is reached, the message WORK MODULATION will appear on the screen. In this
case the thermostove will stop sending hot water to our plant.
3.12

Modification of the boiler water temperature setting

To change the boiler water temperature setting, press key P6 to enter the appropriate menu and with
keys P6 and P7 adjust the required value.
3.13

Stove Status Menu

In this menu, you can check the correct functioning of the most important components of the pellet
stove.
To enter this menu, proceed as follows:
1.
Keep button P4 pressed for 2 seconds, CLOCK SETTING MENU will appear.
2.
Press button P4 4 times: the display will show STOVE STATUS MENU.
3.
Access using button P6: the display will show the desired screen.
4.
Confirm with button P6 to return automatically to MENU' 05 STOVE STATUS. This menu
is for use by a service technician to diagnose performance issues and for the customer
when loading pellets into the pellet hopper when the stove has been completely run out
of fuel.
3.14

Working Hours Menu

The WORKING HOURS Menu shows the total hours of work done by the stove. In some cases, the
working hours may not be zeroed. i.e. numbers similar to 5000/15000/25000 may be shown. The
technician will zero set these numbers when lighting the stove for the first time. A non-zero number
does not mean that the stove has worked for all those hours. It is only a setting given by the programme
during first inspection at Ecoteck, before the stoves are packaged and sent.
To enter this menu, proceed as follows:
1.
Keep button P4 pressed for 2 seconds: CLOCK SETTING MENU will appear.
2.
Press button P4 5 times: the display will show WORKING HOURS MENU.
3.
Access with button P6: the display will show the screen desired.
4.
Confirm with button P6 to return automatically to MENU' 06 WORKING HOURS MENU'.
3.15
Description of Screen Displays & Symbols

3.15.1 Screen Displays

FLOW STAT ON
68°C
10:35 20°C
WORK
BOILER WATER
TEMPERATURE
FIRE POT CLEANING ON
ROOM TEMPERATURE
STOVE STATUS
Figure 12.