3.12 - Serial Menu

RS-232 / RS485 Serial Port Configuration (Common to all)
RS232 Port
Data Rate
Data Format
Flow Control

RS232 PPP Server (Only RS232)

Username
User name to enter to access RS-232 PPP Server.
Password
Password to access RS-232 PPP Server.
Select the IP address of the PPP server. The remote device may be made
Local IP Address
visible on the Ethernet or Wireless networks by either utilising proxy-arp or
routing. The proxy-arp feature may be enabled by setting the Local IP address
the same as the Ethernet IP Address or the Wireless IP Address. The module
will respond on behalf of the remote device, making it seem like the device is
present on the configured network. Alternatively, if the IP address selected is
not the same as the Ethernet or Wireless IP address, routing is used to pass
data to the Ethernet and Wireless ports.
Remote Device IP
Select the IP address of the remote device. Ensure this address is not the
Address
same as any other device on the Ethernet or Wireless networks.
RS-232 / RS485 Serial Gateway Mode
Serial Gateway
Server - Module will wait for a connection to be initiated by a remote Client.
Mode
Character
Enter the maximum delay (in msec) between received serial characters before
Timeout
packet is sent via network.
Packet Size
The number of received bytes that will be buffered before a packet is sent via
the network.
Listen Port
Server Only. Enter the TCP port number on which the server must listen for
(Server)
incoming connections. The standard TELNET port is 23.
Serial Gateway
Client - Module will automatically attempt to connect to the specified remote
Mode
server.
Character
Enter the maximum delay (in msec) between received serial characters before
Timeout
packet is sent via network.
Packet Size
The number of received bytes that will be buffered before a packet is sent via
the network.
Remote Device
Client only. Enter the TCP port number of the remote server (i.e. the remote
Port (Client)
port to automatically connect to).
Remote Device IP
Client only. Enter the IP Address of the remote server.
Address
Serial Gateway
Multicast - Allows point to multi-point serial transfer. All members of the group
will receive serial transmissions made by any other member of the Multicast
Mode
group.
Rev. 2.16 
Select the desired functionality. Select either PPP, Serial Gateway or
Modbus TCP to RTU
The serial data rate desired. Serial data rates available range from 110bps
to a maximum of 115,200bps.
The data format desired. All the standard data formats are supported.
Selects CTS/RTS or None
www.weidmuller.com  
 