Calibrating The Sensor For Contour Cutting; Prepare To Calibrate The Sensor; Figure 34 Registration Tool In Jaw - Ioline Supernova I/S Series User Manual

Table of Contents

Advertisement

52
Ioline SmarTrac User Guide
Hint
Sensor calibration is required
if using any tool other than the
Ioline blade holder (i.e. a ball
point pen). Calibration is also
required to switch back to the
Ioline blade holder after calibrat-
ing for a different tool.
Calibrating the Sensor for
Contour Cutting
The registration sen-
sor is calibrated for
the standard Ioline
cutting tool at the
factory before ship-
ment. If the registra-
tion sensor if ever
replaced or if tools
other than the stan-
dard Ioline blade
holder are used for
registration, use the
following process
Figure 33. Print and measure a 1-cm black square
to recalibrate the
on a white background.
sensor:
Prepare to
Calibrate the
Sensor
1.
Print a black
1-cm square
on a white
background.
Use the sensor
calibration files,
1cm_square.jpg
Figure 34. Registration tool in jaw.
or 1cm_square.
doc, in C:\
Ioline\Calibra-
tion to gener-
ate the square.
Make sure that
there is at least
a margin of 3
inches from
each edge of
the material to
the edges of the
box. Printing
the square in
the center of a
standard sheet
of white paper
is acceptable.
Make sure to
carefully mea-
sure the square
after printing to
ensure that it is
Figure 35. Press the tool down to verify the tip lines
exactly 1-cm.
up with the corner of the box.
1-cm