LANCAST twister 2111-12-01 Installation & User Manual page 15

10mbps media converter
Table of Contents

Advertisement

Upon receiving power, the "twister" media converter goes into
normal operation mode and automatically provides the appropri-
ate signal translation between the connected network segments.
Be sure to verify correct segment connectivity via the LK (link)
LEDs on the front of the unit.
If an additional extension cord is used to connect the power
module to the power source, the following guidelines must be
followed.
While one end of the AC power cord can be fitted with
whatever plug is standard for the country of operation, the
end that connects to the "twister" power supply module must
have a female plug that fits this type of AC receptacle.
• AC 115V (North American): use a UL-listed and CSA-
certified cord set consisting of a minimum 18 AWG, type
SVT or SJT three-conductor cord, a maximum of 15 feet in
length and a parallel blade, grounding-type attachment
plug rated 15A, 125V.
• AC 230V (USA): use a UL-listed cord set consisting of a
minimum No. 18 AWG, type SVT three-conductor cord,
a maximum of 15 feet in length and a Tandem blade
grounding-type attachment plug rated 15A, 250V.
• 240V (outside USA): use a cord set consisting of a
minimum No. 18 AWG cord and grounding-type
attachment plug rated 15A, 250V. The cord set should
have the appropriate safety approvals for the country in
which the "twister" 2111 is installed and marked HAR.
"twister" 2111 Media Converter