8.0
INSTALLATION – DISPENSING TAP CONNECTION
8.1
The hot supply hose should be connected to the OUTLET hose spigot of the AQUATAP
water heating unit. The hose should rise continuously from the heater to the tap without
kinks or twists. If necessary it can be cut to a shorter length, but it should never be
lengthened. The hose should be secured in place on the spigot using the clamp provided.
Warning, only use the hose supplied with the unit or a WRAS approved hose.
Spare hose and clips can be ordered, Product Code 95607364.
8.2
The VENT hose should be connected to the VENT hose spigot of the AQUATAP water
heating unit. The hose should rise continuously from the heater to the tap without kinks
or twists. If necessary it can be cut to a shorter length, but it should never be lengthened.
The hose should be secured in place on the spigot using the clamp provided.
8.3
Fix the control box to a suitable surface near to the dispenser and Aquatap heater using
screws and wall plugs supplied.
8.4
To provide ambient water to the dispenser, tee off a supply from the cold mains
supply to the heater and connect it to the "inlet" side of the control box using the 8mm
straight push fit connector and reducing bush supplied. The dispenser tap chilled/
ambient hose should be connected to the "outlet" pipe of the control box and
secured in place with the pipe clamps supplied.
FIGURE 7 : TAP MOUNTING (BOIL & AMBIENT)
(NOTE: DRIP TRAY/SINK NOT SHOWN FOR CLARITY)
12
CLAMP
WHITE HOSE
HOT TAP
OUTLET
HOSE
TAP
VENT
HOSE
CLAMP
DISPENSER CABLE
SHEATHED CABLE
CONNECTOR
CONTROL
BOX
CONNECTOR
SHEATHED CABLE
FLEXIBLE
HOSE
FUSED SPUR
COLD WATER
SUPPLY