York YAFS012 Installation Manual page 43

Affinity geothermal heat pumps single and dual capacity
Hide thumbs Also See for YAFS012:
Table of Contents

Advertisement

Wiring Schematics cont.
Aurora Advanced with 5-Speed ECM cont.
5 SPEED ECM MOTOR LOW VOLTAGE CONNECTIONS SINGLE SPEED
Model
TAP-1
TAP-2
22
BLUE
30
BLUE
36
BLUE
42
BLUE
RED
48
BLUE
60
BLUE
70
BLUE
5 SPEED ECM MOTOR LOW VOLTAGE CONNECTIONS DUAL CAPACITY
Model
TAP-1
TAP-2
26
BLUE
RED
38
BLUE
49
BLUE
RED
64
BLUE
RED
72
BLUE
RED
Notes
1 - Switch blue and red wires for 208V operation.
2 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
3 – When Auxiliary Heat is field installed the harness will be connected to the auxiliary
heat unit. The auxiliary heat unit will then power the blower. Refer to EAS/EAM/EAL
Auxiliary Heat kit installation instructions. Wires are secured at blower
4 - Refer to units 5 SPEED ECM MOTOR LOW VOLTAGE CONNECTION table for
factory settings.
5 - Y2 input wire Tan not connected on Single Speed units. Wire is secured at blower.
6 - Wires provided for Auxiliary Heat low voltage control. Wires are secured at blower.
7 – Brown blower power wire routed through Current Transducer two times.
8 – Field Connected: Refer to Installation Manual and Auxiliary Heat Instructions for
Current Transducer installation.
9 – Variable speed pump low voltage harness provided with Variable Speed Flow Center.
10 – Variable speed pump power wires to connect the pump to L1 and L2 on the AXB board
are provided with Variable Speed Flow Center.
MODULATING VALVE
AXB BOARD
GND
1
24 VAC
2
C
0-10DC
3
R
ABC BOARD
AID Tool
Communicating
Thermostat
TAP-3
TAP-4
TAP-5
RED
GRAY
RED
GRAY
RED
GRAY
GRAY
RED
GRAY
RED
GRAY
RED
GRAY
TAP-3
TAP-4
TAP-5
TAN
GRAY
RED
TAN
GRAY
TAN
GRAY
TAN
GRAY
TAN
GRAY
CC F
EH1
CC2
P2
ES
LS
ALM
K5-Alarm
ALG
Relay
ACC COM
ACC NO
K6-Acc
ACC NC
Relay
LO
LO
R
R
C
C
O
O/B
G
G
Y1
Y1
Y2
Y2
W
W
DH
DH
P1
RS485 NET
R
C
Green(11)
Traditional
Thermostat
AFFINITY SINGLE & DUAL CAPACITY SERIES INSTALLATION MANUAL
NOTE 5
Gray
Tan
Red
Blue
Optional
UltraTech
CS
RCP
CC2
CC2
CC2
P9
C
P5
R
F FG CC CCG
HI
LO
G
Aurora Base Control™
(ABC)
Com2
Com1
LED4
LED5
G
G
RS485 NET
RS485 EXP
C
R (-) (+)
C
R (-) (+)
CO
P8
P7
P6
Brown(23)
Condensate
43
NOTE 3
Brown
Orange
BLOWER CURRENT
TRANSDUCER
(CT)
Brown
2
1
3
NOTE 1
PS
Blue
240V
Orange
Black
Red
208V
NOTE 4
Black
Transformer
24V
Black/White
RV
FP1
FP2
LP
HP
P4
REVREVFP1 FP1 FP2 FP2 LPS LPSHPSHPS
F1-3A
PWM
Status
CFM
SW1
LED3
G
Test Mode
Fault
LED1
R
Off
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
SW2
Config
LED2
Y
Y1
G
CC
EH1
C
EH2
C
P3
NOTE 6
Black(21)
Black(20)
Electric Heat
Black(22)
P11
5
4
3
Green
2
1
Green
5 Speed ECM
Blower Motor
5
4
3
2
1
C
Yellow
C
R
F
C
P13
On
1
2
3
4
5
6
7
8
To P2 on
Board

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yaft026Yafs070Yaft072

Table of Contents