Installation Instructions - Bosch C 950 ES Installation Manual

Temperature modulated with electronic ignition suitable for heating potable water and space heating
Hide thumbs Also See for C 950 ES:
Table of Contents

Advertisement

Installation instructions

3
Installation instructions
3.1
Specialized tools
The following specialized tools may be required for
installation:
• Manometer
• Multi-meter
• Combustion Gas Analyzer.
3.2
Introduction
Please follow these instructions. Failure to follow
instructions may result in:
B Damage or injury.
B Improper operation.
B Loss of warranty.
Warning: The water heater must be
installed
by
accordance with these instructions. If
improperly installed, a hazardous condition
such as explosion or carbon monoxide
poisoning
could
Thermotechnology
responsible
for
appliances.
Common installation practice is to
i
first
determine
combustion air point of termination,
then design the piping layout back to
the heater.
3.3
Venting
Warning:
B Do
not
reduce
combustion air vent pipe sizes.
B Do not common vent with any other
vented appliance or stove.
B Do not use Type-B vent as the actual
exhaust vent system for the appliance.
Warning: Failure to vent the exhaust
gases to the outside (see Table 2 for
proper
material)
dangerous
flue
structure in which it is installed.
10
a
qualified
installer
result.
Bosch
Corp.
is
not
improperly
installed
the
venting/
the
exhaust
may
result
in
gases
filling
the
Warning: In areas where outside
temperatures routinely come close to
freezing, sealed combustion operation
is required. Concentric termination or
separate terminations for combustion
and vent, must be installed on the same
wall or roof surface; however, never
facing the direction of prevailing winds.
Failure to do so may result in heat
exchanger freezing and bursting. This
failure is not covered under the
manufacturer's warranty.
Warning: Protect the exhaust and inlet
from leaves and debris by installing a
screen on the end of the terminator.
¼" mesh minimum opening
recommended on screen.
3.3.1
Vent material
in
All combustion air and vent pipe materials and fittings
must comply with the following:
Item
Material
PVC schedule 40
Vent or
PVC-DWV
air pipe
and
CPVC schedule 40
fitting
ABS-DWV schedule 40 ANSI/ASTM D2661
PVC
Pipe
cement /
CPVC
primer
ABS
Table 2 Approved vent material
For specific questions concerning vent material,
specifications, usage or installation, please
contact the vent manufacturer directly.
Do not use cellular foam core pipe.
i
or
All vent connections must be glued, except for the
exhaust accessory (see section 3.3.4) which is
screwed into place on the top of the appliance. Slide
the vent pipe into the exhaust accessory. The exhaust
pipe must be properly supported and must be pitched
a minimum of a ¼ inch per foot back to the appliance.
This allows the condensate to drain properly.
An optional concentric vent/air intake termination can
be used for the installation of a vertical or horizontal
venting system. (see Fig. 8).
The concentric vent/air intake body can be ordered
from your local wholesaler. (Part# 196016).
The appliance can also be installed with separate air
intake and exhaust piping (see Fig. 11, Fig. 18 and Fig.
19, page 18).
United States
Canada
ANSI/ASTM D1785
ANSI/ASTM D2665
ANSI/ASTM F441
CSA or ULC
certified only
(ULC-S636)
ANSI/ASTM D2564
ANSI/ASTM F493
ANSI/ASTM D2235
6 720 646 812