Unpacking The Heater - Bosch C 950 ES Installation Manual

Temperature modulated with electronic ignition suitable for heating potable water and space heating
Hide thumbs Also See for C 950 ES:
Table of Contents

Advertisement

Appliance details
• CO ≤ 290 ppm (measured)
• CO
level set from factory, see chapter 6.5, page 43.
2
Dimensions
• Depth (in): 11¼" (286 mm)
• Width (in): 17
7
" (452 mm)
/
8
• Height (in): 30½" (775 mm)
• Weight: 74 pounds (33.5 kg).
Gas types
Natural Gas.
LP Gas.
Voltage
120 V AC (60 Hz) nominal
Amperage
Idle - 40 mA
Operation - ≤ 2.5 A
Noise
45 - 65 db (A)
Safety devices
• Flame failure device (ionization flame rod sensor)
• Overheat prevention (temperature limiter)
• Inlet temperature sensor
• Outlet temperature sensor
• Back flow temperature sensor
• Exhaust gas temperature sensor.
Water protection
IP X4 (protection against water drops)
If appliance is installed at elevations above
i
2000ft, refer to Section 3.3.7 Fan speed
adjustment.
6
2.3

Unpacking the heater

Before installing the unit, be certain you have the
correct heater for your type of Gas - Propane or
Natural Gas. Identification labels are found on the
shipping box, and on the rating plate which is located on
the right side panel of the cover.
Fig. 2
Rating plate
A
Serial number
Type of gas
B
The box includes:
• C 950 ES
• Bracket for wall hanging the heater
• Exhaust vent adaptor (with 4 screws and gasket
provided)
• Combustion air inlet adaptor (with 3 screws and gas-
ket provided)
• Installation manual (manual can be downloaded at
www.bosch-climate.us)
• Product registration card
• Energy Guide label.
Please complete and return the enclosed product
registration card.
The C 950 ES is not approved or designed for:
• Manufactured (mobile) homes, boats or any
mobile installation. (Modular homes are
acceptable for installation).
• Use above 8000 ft A.S.L. altitude (see page 21).
• Outdoor installation without installation of
Outdoor kit (BTOK).
• Applications where inlet water temperature is
higher than 140 °F (60°C). A 3-way valve or
mixing valve must be installed before the
appliance if inlet water temperature exceeds
this limit.
6 720 646 812

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 1050 es

Table of Contents