Installation instructions

Please switch off all fuses immediately with a malfunction.
Immediately shut off the cold water supply to the appliance
should it leak. The malfunction can only be repaired by
factory service or an authorised service agent.
Do not use aggressive or abrasive cleaning detergents!
Do not use a steam cleaner.
Please read this installation and operating instruction
manual carefully, then act accordingly! Store for future
reference.
2
Installation instructions
Install the water heater as described in the illustrated
section. Observe the instructions in the text.
The illustrations can be found in the centre of the instruction
manual.
2.1

Installation

Parts supplied (Fig. 21)
Preparations for installation (Fig. 11)
Leave a gap of at least 30 cm above the top edge of
the appliance housing.
min. 30 mm
Fig. 11
The water heater must be mounted so that it is absolutely
perpendicular. Use a standard pipe joining piece to
compensate for an uneven wall surface (Fig. 26, [2]).
For an additional water connection, use a standard 50 mm
branch adapter (Fig. 26, [3]).
10
max.
Liter
5
4
3
2
1
min.
100°C.
Check the length of the mains connecting cable.
If necessary, fit a longer cable to heater before it is mounted
on the wall (Fig. 25).
WARNING:
Attention!
Unplug the heater from the electricity supply before changing
the cable!
Installation of the mixer tap (Fig. 22, [1–3]).
Detach the mounting plate from the appliance.
Break off the template "S" (Fig. 22, [4]).
Hold the template against the mounting plate and place it
over the mixer tap (Fig. 22, [5]).
Mark the position of the holes for mounting the plate
(Fig. 22, [6]).
Note: Make sure that the mounting plate is absolutely
horizontal!
Any holes in the wall and rawlplugs that remain from a previous
water heater can be used again.
Simply identify the corresponding holes in the mounting plate.
Wall mounting
Fixing the mounting plate (Fig. 23, [1]).
Insert mains cable "A" into the recess – towards right or
left – depending on position of socket (Fig. 23, [2]).
Hook the heater onto the mounting plate (Fig. 23, [3]).
Attach and tighten the water intake and outlet pipes
(Fig. 23, [4]).
Insert the overflow pipe (Fig. 23, [5]).
Setting the water flow rate (Fig. 24)
The maximum water flow rate is 10 l/min, i. e. 1 litre of water
takes 6 seconds to flow into the tank.
Open tap "G" fully.
Adjust the flow rate by turning throttle screw "D" on
the underside of the mixer unit (1/2 turn max.).
Electrical connection (Fig. 25)
The heater should only be connected to a properly
installed, earthed socket.
Do not use a socket strip.
Do not plug the heater in to the electricity supply until it has
been mounted on the wall.
When installation has been completed