Installation Instructions; Specialized Tools - Bosch GWH C 920 ES Instruction Manual

Indoor residential and commercial models temperature modulated with electronic ignition suitable for heating potable water - not approved for space heating purposes (intended for variable flow applications)
Hide thumbs Also See for GWH C 920 ES:
Table of Contents

Advertisement

3

Installation instructions

3.1

Specialized tools

The following specialized tools may be required for
installation:
• Manometer
• Multi-meter
• Combustion Gas Analyzer.
3.2
Introduction
Please follow these instructions. Failure to follow
instructions may result in:
B Damage or injury.
B Improper operation.
B Loss of warranty.
Warning:
The water heater must be installed by a
qualified installer in accordance with these
instructions. If improperly installed, a
hazardous condition such as explosion or
carbon monoxide poisoning could result.
Bosch Thermotechnology Corp. is not
responsible
for
appliances.
Common installation practice is to
i
first
determine
combustion air point of termination,
then design the piping layout back to
the heater.
6 720 608 836
improperly
installed
the
venting/
3.3
Venting
Warning:
B Do
not
reduce
combustion air vent pipe sizes.
B Do not common vent with any other
vented appliance or stove.
B Do not use Type-B vent as the actual
exhuast vent system for the appliance.
Warning: Failure to vent the exhaust
gases to the outside (see Table 2 for
proper
material)
dangerous
flue
structure in which it is installed.
Warning: In areas where outside
temperatures routinely come close to
freezing, sealed combustion operation
is required. Concentric termination or
separate terminations for combustion
and vent, must be installed on the same
wall or roof surface; however, never
facing the direction of prevailing winds.
Failure to do so may result in heat
exchanger freezing and bursting. This
failure is not covered under the
manufacturer's warranty.
Warning: Protect the exhaust and inlet
from leaves and debris by installing a
screen on the end of the terminator.
¼" mesh minimum opening
recommended on screen.
Installation instructions
the
exhaust
or
may
result
in
gases
filling
the
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: