LPR runaway
Error Code
1307 wxx
w = 1 to 3 : Shelf number
xx = 01 to 14 : Slot number
Possible cause of
1.
the malfunction
Countermeasures
Note
None
Troubleshooting
LPR is reset
Check the status of the related card.
Faulty
Enter INS (In-Service) command
from the maintenance terminal.
Check the status of the card.
Faulty
Replace the LPR card.
Enter INS (In-Service) command
from the maintenance terminal.
5.2 Troubleshooting Guide
INS
(In-Service)
INS
(In-Service)
End
263