Toshiba RBC-TRP100E Installation Manual page 17

Hide thumbs Also See for RBC-TRP100E:
Table of Contents

Advertisement

Branch Kit 1:3
<RAV-SM2244AT, SM2804AT series>
Earth screw
Cord clamp
Cord clamp
WARNING
Be sure to attach the provided clamp filter to the power supply wire in order to conform to
EMC standards.
Stripping length power cord and connecting wire
50
Earth line
Indoor/outdoor
connecting wire
Earth screw
1
2
3
10
1
2 3
10
30
(mm)
Connecting wire
Power supply wire
L1
L2
L3
Cord clamp
Clamp filter
(accessory)
10
L1 L2 L3 N
50
Earth line
Power supply wire
16
N
Cord clamp
10
40
EN
EN

Hide quick links: