UNpaCKINg CONT'D
Note. This flue system incorporates a removable flue outlet nose that utilises a push fit location system. This enables the
installation of deflector, high level or balcony outlet flue kits without the removal of the whole 'B' pack terminal. The appliance
must not be operated without the desired outlet nose correctly fitted in place.
Note. Location dimples must be aligned with terminal mounting frame.
pack B Contents Non-Telescopic
A
Flue Terminal
B
Flue Turret
C
Rubber Terminal Wall Seal
D
Cutting Aid
B
pack B Contents Telescopic
A
Telescopic Flue Terminal
B
Flue Turret
C
Rubber Terminal Wall Seal
D
Screw
E
Sealing Tape
8

FRONT paNEL REMOVaL

1. Loosen the 2 screws retaining the front panel.
2. Pull the two spring clips downwards to disengage.
3. Pull the front panel forward and upwards to remove.
Independent + Combi -
INSTALLATION
A
B
A
Installation and Servicing
D
E
D
1
2
C
C
15