SETTING THE TIMER 703 SERIES

Timer Functions for 703 Series Eco timer
The 703 Series boiling water units are
supplied with an „eco‟ timer.
The timer incorporates a „Sleep Delay
Mode‟
which
automatically shut the system down after a
set period of time of no use (2 hours).
To activate sleep delay mode, press and release the „eco‟ button. When the „eco‟
button is released the eco circle surround will illuminate green to indicate the unit is in
sleep delay mode. Power will still be on to maintain set temperature until 2 hours
with no use has lapsed
After 2 hours with no use (from last inlet solenoid valve operation) the unit will go to
sleep at which time „Treq‟ (Treq - temperature required) becomes 0ºC (normally
97˚C). When the unit is in sleep mode „Press eco to heat‟ text will illuminate green.
To „wake up‟ the unit, press and release the „eco‟ button whilst the „Press eco to
heat‟ is illuminated green. When the „eco‟ button is released the eco circle surround
light will be extinguished, sleep mode will be deactivated and operation will return
normal, heating the water to the calibrated value. (approximately 97˚C.)
To deactivate Eco mode, press the eco button whilst the „eco circle surround‟ is
illuminated. When the „eco‟ button is released, the „eco circle surround‟ will be
extinguished and „eco‟ mode is deactivated.
Note: Heating will continue as normal whilst in sleep delay mode until the 2 hour
period of no use time elapses i.e. the „eco‟ button does not need to be pushed
for heating unless the „Press eco to heat text‟ is illuminated.
when
activated
will
15